22
6. USING THE BATTERY
• Slots 1 and 2:
The charger starts charging the battery mounted first. If you place two batteries in the charger, the battery in
slot 1 is charged first, and then the battery in slot 2. (
step 2)
• Charging lamp:
The charging lamp is off when the charger is outside the charging temperature range or when the battery is
mounted incorrectly. If the lamp is still off after the charger falls within its charging temperature range and the
battery is mounted again, contact your local dealer. (
steps 2 and 3)
• Charging time per battery (at 25°C) :
BDC46C
: about 2.5 hours
BDC70 (optional accessory) : about 5.5 hours
(Charging can take longer than the times stated above when temperatures are either especially high or low).
Mount the charged battery.
Type of power source: "36. POWER SUPPLY SYSTEM"
• Use the provided battery BDC46C/BDC70 (optional accessory) for this instrument.
• Before removing the battery, turn OFF the power to the instrument.
• Do not open the battery cover while the power is on.
• When installing/removing the battery, make sure that moisture or dust particles do not come in contact with
the inside of the instrument.
• Waterproofing property for this instrument is not secured unless the battery cover and external interface hatch
are closed, and the connector caps are correctly attached. Do not use it with these open or loose, under the
condition where water or other liquid spills over the instrument. The specification grade for water proofing and
dust resistance is not guaranteed when using USB connector.
• Remove batteries from the surveying instrument or charger before putting into storage.
PROCEDURE Mounting the battery
1. Slide the catch on the battery cover to open.
2. Checking the terminal side on the battery, insert the
battery as shown.
• Do not insert the battery inclined. Doing so may damage
the instrument or battery terminals.
3. Close the battery cover. A click is heard when the cover is
secure.
6.2
Installing/Removing the Battery
Battery cover
Battery