46
GSR1700 CSX Operations Manual
Chapter 5
Power Management
When sufficient power is restored, the receiver will turn on if the
power button is pressed, and the COM port will provide power
according to what the POWERUP configuration specifies. If a
POWERUP configuration is not set on the receiver, the COM port
will provide power if it was already configured to do so before
the power failure. (For details about the POWERUP
configuration, see Section 6.3,
In the case of a prolonged (greater than 30 seconds) power failure
while logging data, the receiver will save the data to internal
memory and close the file before powering off. If this occurs, up
to 10 seconds of data may be lost from the file.
CAUTION
⚠
The receiver may also become inactive if the external power input is
greater than the power specified as acceptable for the receiver. For
more information, see Appendix A,
GSR1700 CSX Operations Manual (OM-1700CSX Rev 2, 750-1-0077).book Page 46 Wednesday, December 3, 2008 2:32 PM