Title: MAN 266, GTecLink Data loggers User Manual
Rev 1.0.1
Page 21 of 32
Battery Lifespan
4.1.3
The following table provides the battery lifespan indicated per
channel (Table 2).
Bear in mind t ha t consumption varies d e p e n d i n g on the sensor
used, sampling rate and enviro nme nt a l conditions.
Table 2: Lifespan indicated for VW-data logger 1 ch (using 1 C-size cell) and VW- data
logger 5 ch. (using 4 C-size cells)
NOTE: Extreme temperatures could cut down t h e c a p a c i t y by 20 to
40%, Check battery specifications. USB not used.
Configuration
4.1.4
The vibrating wire node requires configuration of the sweep frequency
before starting.
There are several existing predefined sweep frequencies:
● Sweep Frequency A (450-1125 Hz)
● Sweep Frequency B (800-2000 Hz)
● Sweep Frequency C (1400-3500 Hz)
● Sweep Frequency D (2300-6000 Hz)
● Custom Sweep Frequency (min value: 300 Hz; max value: 7000 Hz).
To configure data logger radio communications, see section 1.3 of this
manual
.
Number of
sensors
Sampling rate (considering SF 9 14dB)
Sampling rate (considering SF 8 20dB)
30 minutes
5 minutes
30 secs
30 minutes
5 minutes
30 secs
1
> 4 years
> 1 year
6 weeks
> 5 years
> 1 year
11 weeks
5
>7 years
> 2 years
16 weeks
>7 years
> 4 years
23 weeks