3.3

General rules for entering of configuration commands

Activate the terminal window for the configuration via the configuration cable according to the instructions above.
These general rules are valid for entering commands in the command line:

the command must be entered only when a prompt for command appears in front of the cursor mark (colored
or flashing little square); the prompt is either

GW33H7-0#” or

mon” format (see figure

4

);

it is possible to enter only one command each time;

the command could be entered in an alphanumeric character (or several characters);

the command is sent to device by clicking on

ENTER” key. After the command being carried out, the

prompt will appear again and it is ready for a new command to be entered. In case the command fails to
execute, there will appear an error report;

if it takes longer from the last command, due to a loss of communication on the serial line the module may
respond to the command with the error message ”command not found” even if the command is correct. In
that case, just enter the command again. Before entering each command (especially for longer and more
complex commands) it is recommended to ”refresh” the serial line by pressing of ”ENTER” key.

check the execution of the command by displaying of the list of configuration parameters which appears by
entering ”show” or ”/” and pressing on

ENTER” key;

to display a summary of configuration commands and their parameters (

HELP”), enter ”?” (question mark),

or ”/?” and press

ENTER” key;

some subsystems have their own command set. To view a summary (set) of commands for a given subsystem,
enter the set name and the ”?” (question mark). For example, to display a set of commands for the GSM
subsystem, enter the command ”gsm?”. The individual commands for a given subsystem can be entered
by writing of ”distinguishing” command for the given subsystem followed by the command itself (after the
space). For example, setting the APN for GSM communication is done with the command ”gsm apn”, where
”gsm” is the distinguishing command for the GSM subsystem and ”apn” is the command for configuring the
APN. The distinguishing commands for each set are listed at the end of the ”HELP” configuration command
summary;

when entering characters, distinguish strictly the capital and small letters (according to the documentation
or

HELP”);

Do not enter other characters than those listed in

HELP“ or in the documentation, otherwise you would

be risking the unwanted command enter that might be the same as the ones used for manufacturer settings,
diagnostics or service and repair.

WB169-RFG

6

Содержание WB169-RFG

Страница 1: ...WIRELESS COMMUNICATION SYSTEM Wireless M BUS WB169 RFG Revision 1 0 SOFTLINK s r o Tomkova 409 278 01 Kralupy nad Vltavou Czech Republic Phone 420 315707111 e mail sales softlink cz www softlink cz...

Страница 2: ...nd cc subsystems for module initial setting and diagnostics 21 3 4 9 Command of ntp subsystem for setting of time synchronization 21 3 4 10 Command of hist subsystem for examination of History table r...

Страница 3: ...and History menu items 24 7 Table of parameters of the WB169 RFG module that are readable via the optical interface 24 8 Telnet connection to the WB169 RFG module 25 9 Display of the History table of...

Страница 4: ...correctness encodes repacks them into IP UDP frames and sends them to the configured IP address and a central application port number Wireless M Bus messages are packed to the IP UDP frames with usin...

Страница 5: ...rity The module RF transceiver is equipped with the coaxial connector of SMA Female type designated for inter connection of an external antenna directly or via coaxial cable The GSM modem is equipped...

Страница 6: ...GPRS EDGEB3 B8 Antenna characteristic impedance 50 Antenna connector SMA female Configuration interface USB Transmission speed 115 200 Baud Operation mode asynchronous Transmission rate 8 data bits 1...

Страница 7: ...rameters and operational statistics of the module by using of optical converter can be found in the section 3 6 Setting of parameters by using of optical converter The description of checking and sett...

Страница 8: ...rial port that the system automatically assigned to the virtual port at the moment of interconnection module to the computer The number of the serial port can be found in OS Windows by using of Device...

Страница 9: ...rial line by pressing of ENTER key check the execution of the command by displaying of the list of configuration parameters which appears by entering show or and pressing on ENTER key to display a sum...

Страница 10: ...terminal window GW33H7 0 show CPU info CPUID 411fc271 FPU Type 00000002 Flash size 2048 kB Flash bank size 1048576 B 0x00100000 Flash base addr 0x08000000 CPU UID 3339510a001c0036 SW version 1 02 dat...

Страница 11: ...er s password cfgserver Config server IP cfgport Config server port usecfgserver Use config server 0 no 1 yes nepserver Default NEP server IP nepport Default NEP server port Utils loca location 0 63 c...

Страница 12: ...lay 0 timeout 1671 172 16 16 1 status wait stratum 2 reach 3 delay 143 timeout 1681 The meaning of individual commands including subsystem commands is described below 3 4 3 Commands of System commands...

Страница 13: ...xhhmmss format the date value is entered in the format of 0xYYMMDD The manually entered value is automatically corrected when the entries from external synchronization sources GSM or NTP are available...

Страница 14: ...n be performed by using of userpass login oldpassword newpassword command GW33H7 0 userpass admin admin admin223 Password changed GW33H7 0 write Write config 0 GW33H7 0 By using of the nepserver and n...

Страница 15: ...0 errors 0 Tx packets 0 bytes 0 errors 0 Interface eth0 status Down MAC 00 04 d0 ff ff ff Rx packets 0 bytes 0 errors 0 Tx packets 0 bytes 0 errors 0 Interface ppp0 status Up full duplex MTU 1500 IP A...

Страница 16: ...or icmp connection test pin SIM pin useip IP on off usegps GPS on off usetime Sync time on off info show GSM info gps show GPS info cmux show CMUX info lcp show LCP info deb GSM debug write save curre...

Страница 17: ...nication By using of gsm useip gsm usegps and gsm usetime commands with 0 1 parameter the individual services of gsm subsystem can be activated deactivated by gsm useip command the PPP connection to I...

Страница 18: ...wer deb Set debug level write save current configuration cread read configuration show help By using of gw info command basic information about the setting of gw subsystem can be browsed This also inc...

Страница 19: ...servers are displayed in the last lines of the gw info report including the time until the timeout expires In the third part of the file there are records of gateway traffic filters which can be used...

Страница 20: ...are defined by the Wireless M Bus standard The setting can be performed by using of chan1 command followed by the required channel number Current setting can be displayed by using of the command witho...

Страница 21: ...for checking and setting of the basic functions of module operating system as well as the basic communication functions of the module There are following commands Utils loca location 0 63 chars ekey S...

Страница 22: ...s irrelevant for the WB169 RFG module The write cread and clear commands serve for management of saving data in the module memory The module contains two sets of configuration operating configuration...

Страница 23: ...e monitor subsystem can be set This command is intended only for module checking and diagnostics By using of deb command without parameter setting of debug statements of all subsystems can be displaye...

Страница 24: ...to check the current module configuration can be useful in normal operation 3 4 8 Commands of sys disp and cc subsystems for module initial setting and diagnostics The commands of these three subsyste...

Страница 25: ...gateway receives more messages in a given interval the oldest messages are always deleted The History record table is used to monitor the gateway function its records can help to learn which terminal...

Страница 26: ...bols that indicate the status of module main communication channels on top there is a standard image of signal strength symbolizing GSM communication with a graphical representation of GSM signal stre...

Страница 27: ...e module using the optical converter are described in chapter 3 of the manual Configuration of wacoSystem product family devices available at download from the module manufacturer s website The list o...

Страница 28: ...g application can be performed by entering the command ping and the IP address of the module from the command line of any computer Example of perform ing a ping availability check from the Windows Com...

Страница 29: ...le is also equipped with a WEB server which enables display of some module parameters with using the HTTP protocol Currently it is possible to use WEB browser to display the content of the His tory ta...

Страница 30: ...target application IP address The target application is the application that the gateway should send data The setting of target application IP address is dynamic using a mechanism of zero packets The...

Страница 31: ...e is transported through the IP UDP uplink in following three NEP variables The first variable is Message type OID 63 It is a mandatory NEP protocol variable that indicates what type of message it is...

Страница 32: ...cording to individual components of the M Bus address ID Manufacturer Version Medium If for example some specific Medium or Manufacturer codes are entered into the filter only messages with these code...

Страница 33: ...the antenna connector of the device by tension or twist Excessive loads can damage or destroy antenna connectors The module is specified for installation in normal internal premises with the temperatu...

Страница 34: ...d WB169 RFG module Installation of the module should be performed by the following procedure installation of the module can be performed only by a person with necessary qualification in electrical eng...

Страница 35: ...g module turn the power supply off and disconnect the power supply cables from the module Disconnect the signal cable and the antenna cable from the module Release the module from DIN rail by pulling...

Страница 36: ...ntentional shutdown malfunction of the Internet connection caused by a local failure of the GSM network or failure of the PPP connection caused by incorrect functioning of the authorization servers or...

Страница 37: ...in routing or in IP addressing or whether the PIN control of the SIM is turned off If the IP connectivity is most likely available and the power supply is correct LED Power on the module shines perfo...

Страница 38: ...test is positive but the data from some reading modules are not received In this case the problem may be caused by weakening of the signal in the area of the gateway antenna position failure of the ga...

Отзывы: