HYD 3K~6K-EP
User manual
Copyright © Shenzhen SOFARSOLAR Co., Ltd
。
- 52 -
ID029
ConsistentFault_
GFCI
Leakage
current
consistency error
ID030
ConsistentFault_
Vgrid
Grid
voltage
consistency error
ID033
SpiCommFault(D
C)
SPI
communication
error (DC)
ID034
SpiCommFault(A
C)
SPI
communication
error (AC)
ID035
SChip_Fault
Chip error (DC)
ID036
MChip_Fault
Chip error (AC)
ID037
HwAuxPowerFau
lt
Auxiliary power error
ID041
RelayFail
Relay detection failure
ID042
IsoFault
Low
insulation
impedance
Check the insulation resistance between the
photovoltaic array and ground (ground), if
there is a short circuit, the fault should be
repaired in time.
ID043
PEConnectFault
Ground fault
Check ac output PE wire for grounding.
ID044
PvConfigError
Error
setting
input
mode
Check
the
PV
input
mode
(parallel/independent mode) Settings for the
inverter. If not, change the PV input mode.
ID045
CTDisconnect
CT error
Check whether the CT wiring is correct.
ID048
FanFault
FanFault
Please check whether the fan 1 of inverter is
running normally.
ID049
TempFault_Bat
Battery
temperature
protection
Make sure the inverter is installed where
there is no direct sunlight.
Please ensure that the inverter is installed in
a cool/well ventilated place.
Ensure the inverter is installed vertically
and the ambient temperature is below the
inverter temperature limit.
ID050
TempFault_Heat
Sink1
Radiator 1 temperature
protection
ID051
TempFault_Heat
Sink2
Radiator 2 temperature
protection
ID052
TempFault_Heat
Sin3
Radiator 3 temperature
protection
ID053
TempFault_Heat
Sink4
Radiator 4 temperature
protection
ID054
TempFault_Heat
Sin5
Radiator 5 temperature
protection
ID055
TempFault_Heat
Sin6
Radiator 6 temperature
protection
ID057
TempFault_Env1
Ambient temperature 1
protection
ID058
TempFault_Env2
Ambient temperature 2
protection
ID059
TempFault_Inv1
Module 1 temperature
protection
ID060
TempFault_Inv2
Module 2 temperature
protection
ID061
TempFault_Inv3
Module 3 temperature
protection
ID065
VbusRmsUnbala
nce
Unbalanced bus voltage
RMS
Internal faults of inverter, switch OFF
inverter, wait for 5 minutes, then switch ON
inverter. Check whether the problem is
solved.
ID066
VbusInstantUnba
lance
The transient value of
bus
voltage
is
Содержание HYD 3K-6K-EP
Страница 1: ...Shenzhen SOFARSOLAR Co Ltd Energy storage integrated inverter Product Model HYD 3K 6K EP User manual ...
Страница 13: ...HYD 3K 6K EP User manual Copyright Shenzhen SOFARSOLAR Co Ltd 8 ...
Страница 21: ...HYD 3K 6K EP User manual Copyright Shenzhen SOFARSOLAR Co Ltd 16 ...
Страница 36: ...HYD 3K 6K EP User manual Copyright Shenzhen SOFARSOLAR Co Ltd 31 Fig 4 15 Electrical connections Plan A CT ...