Step 1
Remove the insulation layer of an appropriate length according to
figure 4-3, then insert the AC output cable though the PG waterproof cable
gland.
Figure4-3 AC Output Cable schematic diagram
Step 2
Connecting the AC output power cable: The AC output
cable(R,S,T,N and PE) is connected to the terminal block, as shown in
figure 4-4.
Figure4-4 Cable connection schematic diagram
4.4. Connecting Communications Cables
Meter/CT
RS485 Connecting Communications Cables
are used for meter communication,
the electricity meter is shown in the fig.
①
,
Cables
correspond to 24,25
respectively on the electricity meter, as shown in fig.
③
.
The connection mode is
shown in fig.
②
. In position. 2, 5, 8, 10 were respectively connect wires with
corresponding inverter R, S and T phase and zero line is linked together, the
second will be connected to the R phase CT S1 (red) received a position 1
meter, S2 (black) received the meter position. 3, in the same way connected to