socomec COUNTIS E45 Скачать руководство пользователя страница 1

Three-phase Energy meter Measure via CT 

up to 12 000A - M-Bus

COUNTIS 

E45

/

E46

www.socomec.com/en/countis-e4x

COUNTIS E45

COUNTIS E46 - MID

INSTRUCTION MANUAL

EN

Содержание COUNTIS E45

Страница 1: ...Three phase Energy meter Measure via CT up to 12 000A M Bus COUNTIS E45 E46 www socomec com en countis e4x COUNTIS E45 COUNTIS E46 MID INSTRUCTION MANUAL EN...

Страница 2: ...RECOMMENDATIONS 13 8 3 COMMUNICATION STRUCTURE 13 8 4 COMMUNICATION TABLES 13 9 CONFIGURATION 14 9 1 ONSCREEN CONFIGURATION 14 9 1 1 DETAILED VIEW OF MENU SETUP 1 15 9 1 2 VIEW ALL OF THE MENU SETUP 2...

Страница 3: ...EN COUNTIS E45 E46 547983A SOCOMEC 11 DIAGNOSTICS MESSAGES 28 11 1 MISSING PHASES 28 11 2 REVERSED PHASES 28 11 3 MALFUNCTION 28 12 ASSISTANCE 29 13 CHARACTERISTICS 30 14 GLOSSARY OF ABBREVIATIONS 33...

Страница 4: ...s and covers before turning on power to this equipment Always power the device with the correct rated voltage Install the unit following the recommended installation instructions and in a suitable ele...

Страница 5: ...of these instructions thoroughly before commissioning Check the following points as soon as you receive the package containing the unit The packaging is in good condition The unit has not been damaged...

Страница 6: ...tal and partial energy Four tariff management T1 T2 T3 T4 Pulse output Electrical parameter measurements I U V f Bidirectional Power power factor M Bus communication MID Description Reference COUNTIS...

Страница 7: ...cation of current menu 5 Device malfunction Replace the device 6 Active pulse output 7 Active communication 8 Setup menu 9 Main zone 10 Measurement Unit 11 Partials meters Flashing partial meter has s...

Страница 8: ...energy Eap kVAh Total inductive and capacitive reactive energy Er kvarh Total active reactive energy for each tariff T1 T2 T3 T4 Ea Er kWh kvarh Total reactive inductive and capacitive energy for eac...

Страница 9: ...install the device 5 1 Recommendations and safety Refer to the safety instructions section 2 Hazards and warnings page 4 Keep away from electromagnetic interference generator systems Avoid vibrations...

Страница 10: ...OMEC 6 CONNECTION 6 1 Connecting the COUNTIS E45 E46 SET N 1 2 3 4 5 6 L1 A V A A V A A V A L2 L3 Fixed flexible 0 14 mm2 2 5 mm2 0 27 6 9 mm PZ2 4 5 lb in 0 5 Nm max Fixed flexible 1 5 mm2 35 mm2 0 4...

Страница 11: ...iff 1 80 276 VAC DC Tariff 2 M Bus 3 4 M Bus communication Pulse output 5 6 Optocoupler pulse outputs Terminals 5 6 must be supplied with voltage between 5 and 27 VDC 27mA max Mains L1 A Current input...

Страница 12: ...nd to the loads page 11 Fitting terminal covers After connecting the device ensure that the terminal covers are fitted properly and secured by the plastic seals provided with the device Locking the pr...

Страница 13: ...ir 0 5 mm If the distance of 1000 m is exceeded and or the number of devices is greater than 250 add a repeater to allow additional devices to be connected If there are more than 250 units use the sec...

Страница 14: ...ing stages FUNCTION WHERE BUTTONS PRESS Switch menus Every page with the exception of SETUP 1 2 Realtime Switch pages within a menu Every page within a menu Realtime Go to menu SETUP 2 Menu page SETUP...

Страница 15: ...A A V 2 L3 60 Hz 4 5 6 7 5 T1 2 3s x1 Connection diagram x1 3 4 3 3 phases 4 wires 3 currents 3 3 3 3 phases 3 wires 3 currents 3 3 2 3 phases 3 wires 2 currents x1 x1 Tariff management selection x1 C...

Страница 16: ...x1 Secondary M Bus address 0 1 99999998 99999999 the address is specific to each device Baudrate 300 600 1200 2400 4800 9600 Reset energies Ea partial Tariff T1 T2 T3 T4 Ea partial Ea partial Tariff...

Страница 17: ...xample setting the communication address In SETUP 2 mode see page 14 go to the APri primary address screen Example changing the primary address to 243 3s x1 x2 x1 x4 x1 x3 x1 x1 Secondary M Bus addres...

Страница 18: ...riff 1 Imported and exported capacitive reactive energy Tariff 2 Imported and exported capacitive reactive energy Tariff 3 Imported and exported capacitive reactive energy Tariff 4 Imported and export...

Страница 19: ...f 1 Exported active energy tariff 1 Imported inductive reactive energy tariff 1 Exported inductive reactive energy tariff 1 Imported capacitive reactive energy tariff 1 Exported capacitive reactive en...

Страница 20: ...f 2 Exported active energy tariff 2 Imported inductive reactive energy tariff 2 Exported inductive reactive energy tariff 2 Imported capacitive reactive energy tariff 2 Exported capacitive reactive en...

Страница 21: ...f 3 Exported active energy tariff 3 Imported inductive reactive energy tariff 3 Exported inductive reactive energy tariff 3 Imported capacitive reactive energy tariff 3 Exported capacitive reactive en...

Страница 22: ...f 4 Exported active energy tariff 4 Imported inductive reactive energy tariff 4 Exported inductive reactive energy tariff 4 Imported capacitive reactive energy tariff 4 Exported capacitive reactive en...

Страница 23: ...ted active energy L1 L2 L3 Total apparent energy Total imported inductive reactive energy Total exported inductive reactive energy Total imported capacitive reactive energy Total exported capacitive r...

Страница 24: ...Imported partial active energy for tariff T4 Partial imported active energy Exported partial active energy for tariff T1 Exported partial active energy for tariff T2 Exported partial active energy for...

Страница 25: ...983A SOCOMEC 10 6 1 Starting up the partial energy meter x1 Confirm Y OK N Cancel 10 6 2 Stopping the partial energy meter x1 Confirm Y OK N Cancel 10 6 3 Resetting the partial energy meter to zero 3s...

Страница 26: ...realtime readings rt Realtime active power L1 L2 L3 Realtime apparent power L1 L2 L3 Realtime reactive power L1 L2 L3 Realtime phase phase voltage Realtime phase neutral voltage Realtime three phase...

Страница 27: ...metrological firmware version Checksum of metrological firmware Checksum of non metrological firmware Installed communication port Connection type 3 phases 4 wires 3 CT 3 phases 3 wires 3 CT 3 phases...

Страница 28: ...sing phases If one or several phases are not detected the exclamation point flashes on the screen Example phase not detected 11 2 Reversed phases If a 123 phase sequence is detected the symbol appears...

Страница 29: ...SSISTANCE Causes Solutions Device not working Check the neutral and phase 1 cable connections Phases not shown onscreen Check the connections Phases reversed onscreen Check the network configuration E...

Страница 30: ...s T1 T2 T3 and T4 CURRENT MEASUREMENTS Type via current transformers CT burden for each phase 0 04 VA Startup current Ist 2mA Class 1 1mA Class C Minimum current Imin 0 10 A Transition current Itr 50m...

Страница 31: ...2 Ea Er DISPLAY Type 8 digit LCD with backlight Refresh time 1 s Backlight activation time 10 s Active energy 1 display 8 digit 00000 000 kWh 999999 99 MWh Reactive energy 1 display 8 digit 00000 000...

Страница 32: ...ge temperature 25 C to 75 C Humidity 80 Installation Internal box cabinet Vibrations 0 075 mm HOUSING Dimensions W x H x D mm Modular width of 4 modules DIN 43880 72 x 90 x 64 Mounting On DIN rail EN...

Страница 33: ...for Tariff 4 tot Total menu PAr b Partial readings and energy balance menu rt Realtime values menu SEtuP 2 Setup 2 menu Addr Slave address bAud Communication speed in bauds bits per second Prty Commun...

Страница 34: ...547983A Non contractual document 2020 Socomec SAS All rights reserved CORPORATE HQ CONTACT SOCOMEC SAS 1 4 RUE DE WESTHOUSE 67235 BENFELD FRANCE www socomec com...