socomec COUNTIS E27 Скачать руководство пользователя страница 1

COUNTIS E27

COUNTIS E28 - MID

www.socomec.com/en/countis-e2x

Three-phase energy meter 

Direct - 80 A Ethernet

COUNTIS 

E27

/

E28

INSTRUCTION MANUAL

EN

Содержание COUNTIS E27

Страница 1: ...COUNTIS E27 COUNTIS E28 MID www socomec com en countis e2x Three phase energy meter Direct 80 A Ethernet COUNTIS E27 E28 INSTRUCTION MANUAL EN...

Страница 2: ...neral information 12 8 2 Communication structure 12 8 3 Communication tables 12 9 CONFIGURATION 13 9 1 Onscreen configuration 13 9 1 1 View all of the menu SETUP 2 14 9 1 2 Detailed view of menu SETUP...

Страница 3: ...3 EN COUNTIS E27 E28 545881A SOCOMEC 1 DOCUMENTATION All documentation on the COUNTIS E27 E28 is available on the website at the following address www socomec com en countis e2x...

Страница 4: ...device with the correct rated voltage Install the unit following the recommended installation instructions and in a suitable electrical cabinet Failure to take these precautions could cause death or...

Страница 5: ...e instructions thoroughly before commissioning Check the following points as soon as you receive the package containing the unit The packaging is in good condition The unit has not been damaged during...

Страница 6: ...Measures and displays total and partial energy Dual tariff management T1 T2 Electrical parameter measurements I U V f Power power factor TCP Modbus communication MID version according to reference De...

Страница 7: ...Device malfunction Replace the device 6 Active pulse output 7 Active communication 8 Setup menu 9 Main zone 10 Measurement Unit 11 Partials meters Flashing partial meter has stopped 12 Tariff display...

Страница 8: ...kVAh Eap per phase Total reactive inductive and capacitive energy Er kvarh Er per phase Total active reactive and apparent energy for each tariff T1 T2 Ea Er kWh kvarh Ea Er Eap per phase kWh kvarh kV...

Страница 9: ...o the safety instructions section 2 Hazards and warnings page 4 Keep away from electromagnetic interference generator systems Avoid vibrations with accelerations greater than 1 g for frequencies lower...

Страница 10: ...S E27 and E28 are intended for three phase networks with neutral SET N A A V A A V A A V L1 L2 L3 L1 L2 L3 N 3 x 80A 230 400 VAC 50 60 Hz 2 1 Ethernet Ethernet RJ45 The Ethernet cable must pass twice...

Страница 11: ...the loads page 10 Fitting terminal covers After connecting the device ensure that the terminal covers are fitted properly and secured by the plastic seals provided with the device Locking the program...

Страница 12: ...r slave structure Communication is via TCP Transmission Control Protocol through the Ethernet communication port The default IP address is IP address 192 168 0 4 Subnet Mask 255 255 255 000 Gateway 19...

Страница 13: ...ng stages Function Where Buttons Press Switch menus Every page with the exception of SETUP 1 2 Realtime Switch pages within a menu Every page within a menu Realtime Go to menu SETUP 2 Menu page SETUP...

Страница 14: ...different screens by pressing 3s IP address 1 IP address 2 IP address 3 IP address 4 Netmask 1 Netmask 2 Netmask 3 Netmask 4 Gateway 1 Gateway 2 Gateway 3 Gateway 4 Reset partial energy to zero Ea par...

Страница 15: ...ss 3 000 001 254 255 IP address 4 000 001 004 254 255 Netmask 1 000 001 254 255 Netmask 2 000 001 254 255 Netmask 3 000 001 254 255 Netmask 4 000 001 254 255 Gateway 1 000 001 192 254 255 Gateway 2 00...

Страница 16: ...hanging the communication address to IP 007 3s x1 Default Ethernet settings Eth SdEF x1 Confirm Y Save changes and exit N Exit without saving C Continue without saving x1 x1 x2 x1 x5 x1 x5 x1 x1 IP ad...

Страница 17: ...riff 1 Imported and exported capacitive reactive energy Tariff 2 Imported and exported capacitive reactive energy Total imported and exported inductive reactive energy Partial exported active energy b...

Страница 18: ...f 1 Exported active energy tariff 1 Imported inductive reactive energy tariff 1 Exported inductive reactive energy tariff 1 Imported capacitive reactive energy tariff 1 Exported capacitive reactive en...

Страница 19: ...f 2 Exported active energy tariff 2 Imported inductive reactive energy tariff 2 Exported inductive reactive energy tariff 2 Imported capacitive reactive energy tariff 2 Exported capacitive reactive en...

Страница 20: ...ted active energy L1 L2 L3 Total apparent energy Total imported inductive reactive energy Total exported inductive reactive energy Total imported capacitive reactive energy Total exported capacitive r...

Страница 21: ...Imported partial active energy for tariff T2 Partial imported active energy Exported partial active energy for tariff T1 Exported partial active energy for tariff T2 Partial exported active energy Par...

Страница 22: ...881A SOCOMEC 10 4 1 Starting up the partial energy meter x1 Confirm Y OK N Cancel 10 4 2 Stopping the partial energy meter x1 Confirm Y OK N Cancel 10 4 3 Resetting the partial energy meter to zero 3s...

Страница 23: ...realtime readings rt Realtime active power L1 L2 L3 Realtime apparent power L1 L2 L3 Realtime reactive power L1 L2 L3 Realtime phase phase voltage Realtime phase neutral voltage Realtime three phase...

Страница 24: ...C 10 6 Detailed view of the menu info Metrological firmware version Non metrological firmware version Checksum of metrological firmware Checksum of non metrological firmware Installed communication po...

Страница 25: ...d 11 2 Reversed phases If a 123 phase sequence is detected the symbol appears If a 132 phase sequence is detected the symbol appears 11 3 Malfunction If you see this message the meter has malfunctione...

Страница 26: ...mption 0 5VA max per phase Startup current Ist 20mA Minimum current Imin 0 25A Transition current Itr 0 5A Reference current Iref 5A Permanent overload lmax 80A Intermittent overload 30 Imax for 1 2 c...

Страница 27: ...4 digit 00 00 99 99 kvar Realtime reactive power 1 display 4 digit 00 00 99 99 kVA Realtime voltage 1 display 4 digit 000 0 999 9 V Realtime current 1 display 4 digit 00 00 99 99 A Power factor 1 dis...

Страница 28: ...s W x H x D mm Modular width of 4 modules DIN 43880 72 x 90 x 64 Mounting On DIN rail EN 60715 Connection capacity tightening torque See chapter 6 Connection page 10 Protection index Front IP51 casing...

Страница 29: ...u PAr b Partial readings and energy balance menu rt Realtime values menu SEtuP 2 Setup 2 menu Addr Slave address bAud Communication speed in bauds bits per second Prty Communication frame parity n No...

Страница 30: ...Non contractual document 2017 Socomec SAS All rights reserved 545881A CORPORATE HQ CONTACT SOCOMEC SAS 1 4 RUE DE WESTHOUSE 67235 BENFELD FRANCE www socomec com...

Отзывы: