17_
SP
R_
GB
www.socosystem.com
MANUAL
SOCO Power Roller - SPR
Страница 1: ...9724740011_2008 12 17_SPR_GB www socosystem com MANUAL SOCO Power Roller SPR...
Страница 2: ...Safety 4 2 1 Safety in general 4 2 2 Disposal 4 3 Survey 5 3 1 Survey of SPR 5 4 Operation application and compatibility 6 4 1 Operation 6 4 2 Application 6 4 3 Compatibility 7 5 Accumulation systems...
Страница 3: ...s manual contains all information relating to safety required in connection with installation operation and maintenance of the product This is a standard manual and changes may have been made in conne...
Страница 4: ...uld not be disposed of as unsorted municipal waste Please utilize your local WEEE collection facilities in the disposal of this product and otherwise observe all applicable requirements Our products c...
Страница 5: ...gh power supply White 2 Direction Required direction of rotation To SPR 0 VDC anti clockwise seen from the supply end of the roller 24 VDC clockwise seen from the supply end of the roller Grey 6 Accu...
Страница 6: ...to its accumulation current limit If the motor stops due to exceeding of the current limit 24 VDC is switched to its Status wire The signal is reset to 0 VDC when the motor has started again 4 2 Appl...
Страница 7: ...Stop are then to be controlled by means of the yellow Status wire Note 0 VDC Start 24 V DC Stop The direction of rotation of the motor is changed by switching 24 V DC to the white Direction wire e g b...
Страница 8: ...roller conveyor into equally large zones A zone consists of an SPR and a number of non driven rollers The non driven rollers are driven by an SPR by means of a belt drive If the zone is to have zero...
Страница 9: ...exceeds nominal current when the item is blocked This means that factors such as base dimensions number of non driven rollers and the rolling friction paper quality of the transported item are also im...
Страница 10: ...or the like with a 24 V DC PNP outlet The transmitter is connected to PSB1 terminal strip KL1 according to diagram Examples If items are removed automatically or manually from the accumulation convey...
Страница 11: ...tems A transmitter is placed in each zone approximately 100 150 mm before the outlet end of the zone The distance is chosen so that the heaviest item to be conveyed has time to brake within the zone P...
Страница 12: ...yance of items Connect an external contact signal between terminals 13 and 14 on KL1 in PSB1 When the contact signal is opened SPR1 starts and item no 1 is conveyed onward When S1 is no longer activat...
Страница 13: ...nute How is the roller used Pressureless accumulation pressure accumulation or continuous accumulation Error Action SPR does not rotate Check wires from the roller visually Is the cable damaged or has...