MV-805 IP Multiviewer User Manual
System-Setup Template
RollCall Templates 6.2
Issue1 Revision 1
Page 53
© 2018 SAM
Setting
Description
Interface
Drop-down menu.
Select the physical network interface to configure:
•
Control : eno1.
•
Control 2 : eno2. (See
Note 1
.)
•
ens2f0 : ens2f0. (Media IP fabric connection)
•
ens2f1 : ens2f1. (Media IP fabric connection)
•
ens1f0 : ens1f0. (Media IP fabric connection, MV-805-32-only)
•
ens1f1 : ens1f1. (Media IP fabric connection, MV-805-32-only)
Note:
Each physical network interface may be renamed in the template.
The name that appears in the template’s drop-down menu is formed from the name
and the identifier: “name : identifier”.
For example, “Control : eno1”.
IP Address
Text box.
Static IP address of the selected interface. (IPv4)
Click the
S
button to locally save the new setting.
Subnet Mask
Text box.
Subnet mask of the selected interface. (IPv4)
Click the
S
button to locally save the new setting.
DHCP
Check box.
Tick to enable dynamic host configuration protocol (DHCP) on the selected interface.
Click the
S
button to locally save the new setting.
Interface Name
Text box.
Enter a “friendly” name for the interface.
Click the
S
button to locally save the new setting.
Default Gateway
Address
Text box.
Static IP address of the gateway for the selected interface to use. (IPv4)
Click the
S
button to locally save the new setting.
Primary DNS IP
Address
Text box.
Static IP address of the primary Domain Name System (DNS) server for the selected
interface to use. (IPv4)
Click the
S
button to locally save the new setting.
Secondary DNS IP
Address
Text box.
Static IP address of the secondary DNS server for the selected interface to use. (IPv4)
Click the
S
button to locally save the new setting.
Note 1:
Network interface “Control 2 : eno2” (i.e. the second control network interface) may not
appear in the drop-down menu unless there is a network connection to the rear of the unit.
Table 11 Network Interface Settings
Note:
Media IP Fabric Interfaces and network connection:
•
‘ens2f0’ and ‘ens2f1’ must be connected to a different IP fabrics.
•
‘ens1f0’ and ‘ens1f1’ must be connected to a different IP fabrics. (MV-805-32)