Compact Scan Module (CSM)
Technical Specifications
42
Software Restart Procedure
This method, which closes and restarts the ShopStream Diagnostic Suite software,
takes about two minutes to complete.
z
To restart the ShopStream Diagnostic Suite:
1.
Navigate to the Home Screen on the diagnostic tool.
2.
Select
Exit
to close the ShopStream Diagnostic Suite.
3.
Wait for the CSM Communication LED to stop flashing.
4.
Select the
ShopStream Diagnostic Suite
icon on the desktop.
The ShopStream Diagnostic Suite should open with connectivity restored.
Windows Reboot Procedure
This method, which completely shuts down the diagnostic tool, takes several
minutes to complete.
z
To reboot the diagnostic tool:
1.
Disconnect the CSM from the vehicle.
2.
Navigate to the Home Screen on the diagnostic tool.
3.
Select
Exit
to close the ShopStream Diagnostic Suite.
4.
Select
Start
in the lower-left corner of the screen to open the menu.
5.
Select
Turn Off Computer
from the menu.
6.
Select
Turn Off
when the Confirmation window opens.
7.
Wait for the tool to completely turn off, then press the
Power
button to restart
the diagnostic tool.
8.
Connect the CSM to the vehicle once the ShopStream Diagnostic Suite opens.
4.9 Technical Specifications
Item
Description / Specification
Communications
Wireless
Bluetooth
®
2.1 Technology
Operating Range
Approx. 50 feet (15.24 m)
USB Power
5V @ 500mA
DC Operating Power
8V to 32V, Maximum 10 Watts
Width
1.85 in. (47 mm)
Height
0.92 in. (23.4 mm)
Depth
4 in. (101.6 mm)
Weight
0.22 lb (100 g)
Operating Temperature
Range (ambient)
At 0 to 90% relative humidity (non-condensing)
32 to 113°F (0 to 45°C)
Storage Temperature
(ambient)
At 0 to 70% relative humidity (non-condensing)
–4 to 140°F (–20 to 60°C)
Operating Altitude
Maximum 2000 m
Environmental Conditions
This product is intended for indoor use only
This product is rated for Pollution Degree 2 (normal
conditions)
Содержание Zeus
Страница 1: ...User Manual ZEEMS342A Rev F TM Start BC ...