background image

OPERATION IN SINGLE SEQUENTIAL ACTUATION MODE
To select the Single Sequential Actuation Mode (see
Figure 1): 

1. Press and hold the red Actuation Selector embedded

in the trigger.

2. Rotate Actuation Selector down to the Single

Sequential Actuation (T).

3. Release Actuation Selector, ensuring locking tab is

fully seated in the slot.

Ensure selector has locked into position. Ensure 

actuation process is fully understood before attempting to use angled 
finish nailer.

TO USE THE ANGLED FINISH NAILER IN SINGLE SEQUENTIAL 
ACTUATION MODE:
1. Firmly grip angled finish nailer 

handle.

2. Position angled finish nailer work

piece contact on work piece surface.

3. Push angled finish nailer against

work piece compressing work piece
contact.

4. Pull trigger on angled finish nailer to

drive nail. The angled finish nailer will
recoil away from the work piece as
nail is driven.

5. Remove finger from trigger and lift

angled finish nailer away from surface
of work piece.

OPERATION IN CONTACT ACTUATION MODE

When using contact actuation mode, be careful of unin-

tentional double fires resulting from tool recoil. Unwanted fasteners may be
driven if the work piece contact is allowed to accidentally re-contact the work
piece.

9

To improve the connection between the quick disconnect and air nailer, and to help
prevent oxidation, apply PTFE tape or joint compound to the connector threads
before insertion. 

3. Snap the air hose onto the quick disconnect on the air nailer. Check for air

leaks.

LUBRICATION
To ensure maximum performance, it is recommended to install an air set (oiler, reg-
ulator, and air filter) as close as possible to the air nailer. Adjust the oiler so that
approximately one drop of oil will be released for every 50 nails.

If an air set is not used or is unavailable, oil the tool using pneumatic tool oil by plac-
ing 2 or 3 drops into the air inlet. This should be done before and after use.  For
proper lubrication, the tool must be fired several times after the oil is introduced to
the filter.

OPERATING THE FINISH NAILER 

Always use hearing protection to protect your ears against
hearing loss due to exhaust noise. Always wear proper safe-
ty glasses to prevent injuries to the eyes from fragments of

the work piece, defective nails or other debris caused by using the angled
finish nailer. 
All safety glasses must have side shields and should conform to
the requirements of the American National Standards Institute (ANSI) z87.1.
Failure to comply with this warning could lead to serious or permanent damage
to the ears as well as serious damage or permanent blindness in the eyes. 

Always disconnect the air hose before making adjustments or checking the
functionality of the air nailer.

SELECT TRIGGER ACTUATION MODE

The angled finish nailer is equipped with a selectable trigger. This allows the selec-
tion of Single Sequential Actuation Mode or Contact Actuation Mode.

Figure 1

10

Содержание 870013

Страница 1: ...NAILER INSTRUCTION MANUAL THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY OPERATION MAINTENANCE AND STORAGE OF THIS PRODUCT BEFORE USE READ CAREFULLY AND UNDERSTAND ALL CAUTIONS WARNINGS INSTRUCTIONS AND PRODUCT LABELS FAILURE TO DO SO COULD RESULT IN SERIOUS PERSONAL INJURY AND OR PROPERTY DAMAGE IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCE A PROBLEM WITH YOUR SNAP ON PRODUCT DO NOT...

Страница 2: ... alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death DANGER indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING indicates a potentially hazardous situation which if not avoided could result in death or serious injury CAUTION indicates ...

Страница 3: ...ed finish nailer is being used Distractions can result in severe injury or even death to anyone who inadvertently gets in the way of nailing operations Do not use oxygen combustible or bottled gases such as carbon dioxide or nitrogen as a power source for the angled finish nail er Use only compressed air from a source as outlined in this man ual The tool will explode resulting in severe injury or ...

Страница 4: ... work area should be clear and free of litter Do not connect angled finish nailer to an air source capable of generating more than 200 psi 14 06 kg cm2 G Over pressurizing the angled finish nailer will result in bursting abnormal operation or breakage of the tool Use only clean dry regulated compressed air at levels specified on the tool Failure to comply can cause severe injury or death to the op...

Страница 5: ...n inside diameter of 1 4 6 5 mm or greater and a hose length of less than 6 6 ft 20 m it is recommended that a 0 5 second interval be allowed between each nailing Air supply hoses shall have a minimum working pres sure of 150 psi 10 7 kg cm2 G or 150 of the maximum pressure produced by the compressor or whichever is higher Low air output by the compressor or a longer hose with a smaller inside dia...

Страница 6: ...und to the connector threads before insertion 3 Snap the air hose onto the quick disconnect on the air nailer Check for air leaks LUBRICATION To ensure maximum performance it is recommended to install an air set oiler reg ulator and air filter as close as possible to the air nailer Adjust the oiler so that approximately one drop of oil will be released for every 50 nails If an air set is not used ...

Страница 7: ... ment knob is already set to its lowest setting decrease the air pressure Should nails be driv en too deep even when the adjustment knob is set at its lowest setting decrease the air pres sure In general the angled finish nailer will have a longer service life when the adjustment knob is set a lower setting causing less wear and tear on the driving mechanism Always disconnect the air nailer before...

Страница 8: ...ll the trigger fully and hold it in the fired position for 1 to 2 seconds before releasing the trigger This will give the air nailer time to completely expend the previous nail and build enough pressure for the next nail 14 In order to prevent the surface of the work piece from being scratched or damaged use the nose adapter Install nose adapter by fitting the protrusion on the inside of adapter w...

Страница 9: ... be secured in a locked location to prevent unauthorized usage Avoid exposure to direct sunlight and or locations with high humidity and heat DO NOT hold the trigger in a half pulled position This could cause an unexpected nailing to occur if the work piece contact is permit ted to re contact the work piece Failure to comply could result in damage to work piece CHANGING DIRECTION OF EXHAUST AIR Th...

Страница 10: ...every use using pneumatic tool oil Extends life of angled finish nailer Apply 2 3 drops of pneumatic tool oil to angled finish nailer air inlet after every use Nailer operates but no nail is driven Check for jammed nail Ribbon spring weakened or damaged Inspect nail feeder mechanism Ensure correct nails are being used Clear jammed nail Replace ribbon spring Clean and lubricate nail feeder Use ONLY...

Страница 11: ... 2731 Spring 8 A0308 0101 Disc Valve 9 A0200 0051 O Ring 13 8 2 4 10 A0200 0531 O Ring 48 2 5 11 A0311 0581 Seal Air 12 A0103 0221 Ring 13 A0200 0131 O Ring 35 3 5 PROBLEM POSSIBLE CAUSE SOLUTION PARTS DIAGRAM 19 Drives nails properly during normal nailing operations but fails to drive nails fully at faster operating speeds Check inside diameter of air hose Switch to air hose with larger inside di...

Страница 12: ...mper 34 A0401 2071 Body 35 A0004 0021 Nylon Nut M5 36 A0205 0611 Gasket 37 A0316 0321 Hook 38 A0203 0191 Filter 39 A0306 1161 Tail Cover 40 A0011 0161 Spring Pin 3 24 41 K0500 1511 Trigger Set 42 A0005 0311 Pin Retainer 5 5 2 43 A0011 0241 Spring Pin 3 26 44 A0712 1261 Release Catch Guide 45 A0100 0461 Spring 46 A0000 0031 Screw M4 3 5 47 A0711 2831 Release Catch B 48 A0714 0671 Adjustment Wheel 4...

Страница 13: ...Wheel 71 A0006 0451 Guide Pin 72 A0707 0741 Pusher Site 73 A0101 0161 Spring 74 K0300 3181 Head Valve Assembly 75 K0600 1891 Piston Unit 76 K0300 3561 Cylinder Set 77 K0300 3201 Spacer Set 78 A0307 0041 Air Plug MODEL NUMBER 870013 AIR PRESSURE 70 120 PSIG 5 0 8 5 kg cm2G NAIL LENGTH 1 1 4 12 5 mm 2 1 2 25 mm NAIL CAPACITY 110 NAILS MINIMUM HOSE DIAMETER 1 4 6 5 mm NAIL DIAMETER 15 GAUGE NET WEIGH...

Страница 14: ... SNAP ON portable air tool and no one else all parts of the product except those parts referred to below which are specifically excluded from such warranty see Exclusions to be free from defects in materials and workmanship for a period of one year from the original date of purchase The date of purchase shall be the date of shipment to the original purchaser or the date the original purchaser took...

Страница 15: ...HTS CLAIMS AND OR CAUSES OF ACTION ARISING THEREFROM OR BASED THEREON PURCHASER S SOLE AND EXCLUSIVE REMEDY IS AS STATED ON PRECEDING PAGES LIMITATIONS OF LIABILITY IN NO EVENT SHALL ALLTRADE AND OR ITS REPRESENTATIVE S BE LIABLE FOR INDIRECT INCIDENTAL SPECIAL AND OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF OR RELATED TO DIRECTLY OR INDIRECTLY ANY BREACH OR PROVISION OF ANY AGREEMENT BETW...

Отзывы: