SMSCOM TwinController Series Скачать руководство пользователя страница 1

Manual

The 

TwinController

 is software controlled with 

MOTION FLOW 

and not mechanical like other 

controllers. Therefore, it reacts completely differently to the usual controllers. 

The 

TwinController

 make an evaluation for the gradual increase or decrease of your fans. 

In the course off a cycle it will automatically find the appropriate constant capacity level of the fans to 

maintain programmed temperature. 

This new technique means no more temperature fluctuations and fan noise is kept to a minimum.

Fans of different capacities

Because of the use of using ventilators of different capacity i.e. 1500m3 and 2250m3 

the 

TwinController 

will create an optimal pressure inside your room.

Please make sure the smaller vantilator is plugged into the inlet socket (FAN AIR IN)  

The bigger fan plugs into the exhaust socket (FAN AIR OUT). 

Usage

1. Connect the ventilators to the BLUE sockets (Small Fan=IN / Big Fan=OUT)

2. Set the MINIMUM ventilation speed (e.g. 30%) using dail knob1 

3. Set the temperature (e.g. 25°C) using dail knob2

4. Set the MAXIMUM ventilation speed (e.g. 95%) using dail knob3 

5. Place the Temperature Sensor in the middle of the room making sure it is not placed directly in the air flow.

6. Plug the Switchbox into the mains socket and turn on*

Of course you also can use only 1 ventilator if desired using 

‘FAN AIR OUT’

 socket only.

The 

TwinController

 will automatically find the right speed for the ventilators to maintain the desired 

temperature. 

*When the 

TwinController 

is first turned on, it will scan the room for 5 minutes to find the correct 

speed for the fans. During this time, the ventilators will start running faster and slower as 

the 

TwinController

  calibrates. After this scanning process the 

TwinController

  

will always know the correct running speed for your ventilators and will adjust them accordingly.

Attention: Set a suitable minimum speed for your ventilators! (If set too low, the ventilators may make 

some noise and the air will not be refreshed adequately.)

Technical Specifications

Adjustable Capacity:   Max 4.5A  

  

  Max 7A   

 

  Max 14A

Input: 

  

    230/240V Phase   

  230/240V Phase   

  230/240V Phase

Frequency: 

     50Hz   

 

  50Hz 

 

 

  50Hz

NTC Temperature:       200cm Sensor 4K7 at 25ᵒC    500cm Sensor 4K7 at 25ᵒC    500cm Sensor 4K7 at 25ᵒC

TwinController

4.5A | 7A | 14A

Отзывы: