4.2.2.2 Recommended Operating Conditions
Parameter
Min
Typ.
Max
Unit
Operating (ambient) temperature
21
°C
Table 4-8: Recommended Operating Conditions
4.2.2.3 6-pin Active-Pod for High Speed MediaLB Debug Header
DC characteristics:
Parameter
Min
Typ.
Max
Unit
Input resistance
50
k
Ω
Input capacitance
3
5
8
pF
Input common voltage
0.05
2.35
V
Input differential threshold
±7
±50
mV
Table 4-9: 3-pin Active-Pod for High Speed MediaLB Debug Header DC Characteristics
4.2.2.4 Mechanical Characteristics
•
Protection Rating:
IP 42
•
Dimensions:
Active-Pod (High Speed):
35 / 22 / 8 mm (L / W / H)
Active-Pod
cable:
40
cm