068000xxx  Iss 01 

Fig 2 – Mounting Slot 

Model 

 

 

 

 

 

SS3E 

500 

540 

95 

30 

 

 

I

NSTALLATION 

R

ECOMMENDATIONS

 

 

 

It is recommended that careful thought be given to siting the appliance within the room.  Try to 

avoid  being  directly  in  front  of  the  heater  for  long  periods.    Consider  where  you  may  stand,  at  a 
work surface or the like.  Position the heater to deliver the benefit of its warmth but not so as to 
overheat yourself. 
 

The heater must not be located immediately below a fixed socket outlet. 

 

I

NSTALLATION 

R

EQUIREMENTS

 

                                                                               
 

The appliance is designed to fit behind 

the  plinth  board  and  below  the  base  shelf 
of  a  kitchen-type  cupboard  ie  within  the 
free  plinth  space.    Figure  1  below  shows 
the MINIMUM size cupboard unit into which 
the appliance may be fitted. 
 
 

The  appliance  may  be  installed  into  a 

cupboard with dimensions larger than those 
given above. 

 

I

NSTALLATION PROCEDURE

 

 

1.

 

Cut a hole in the plinth board, to the dimensions 
given in Figure 2. 

2.

 

The power supply cable must be routed from the 
connecting unit into the plinth space.  The cable 
shall  be  sufficiently  long  as  to  pass  through  the 
plinth space and plinth board.  This enables the 
appliance  to  be  subsequently  withdrawn  from 
the plinth if maintenance is required.  Ensure no 
sharp  edges  are  present  along  the  power  cable 
route. 

3.

 

The appliance can now be slid through the plinth 
board,  until  the  fascia  panel  abutts  the  outside 
of  the  plinth  board.  Screw  the  fascia  panel  to 
the plinth board with the screws provided. 

4.

 

Connect  the  unit to the mains  power  supply  in 
accordance  with  the  appropriate  section  of 
these instructions. 

 

To  remove  the  appliance  from  the  plinth  space,  should  maintenance  be  required,  disconnect 

mains power supply, unscrew fascia panel and slide out the appliance. 

 
These dimensions are for a 600mm wide by 100mm  high plinth.  If the appliance is to be fitted 

into a plinth greater in length than specified then the hole shown in Figure 2 must be cut at least 
22mm from one end. 

 
If the supply cord on this appliance is damaged, it must be replaced by a special cord which is 

only available from an Authorised Service Agent, or your supplier.  If replacement of the supply cord 
is found to be necessary, the following should be noted. 

 

 

A

IRFLOW

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

OPERATION

 

The square red switch on the left hand side switches the unit on and connects the mains supply to 
the fan motor (giving a cool airflow) and energises the heat control switches. 
 

HEAT CONTROL

 

When  the  left  switch  on  the  right  hand  side  is  depressed  it  will  illuminate  and  the  heat  output  is 
1kW.  When the right-hand switch is depressed it will illuminate and the heat output is 2kW.  When 
both switches are depressed the heat output is 3kW.   

 

 

The  appliance  is  fitted  with  an  electronic  Safety  Control  (ES).    This  is  a  safety  device  which 

switches  off  the  heater  if,  for  any  reason,  the  appliance  overheats.    The  ES  Controls  can  only  be 
reset after the appliance has cooled down.  In order to reset the ES Control proceed as follows: 
1.

 

Switch off appliance and leave for approximately 5 minutes. 

2.

 

Switch on appliance and ES Control will reset. 

3.

 

Ensure  that  the  appliance  is  functioning  correctly.    If  the  ES  Control  operates  again,  the 
appliance should be checked by a competent electrician. 

 

C

ONNECTION TO THE 

M

AIN 

S

UPPLY

 

 
 

Electrical installation should be carried out by a competent installer, preferably registered with 

NICEIC (National Inspection Council for Electrical Installation Contracting) in accordance with the 16 
edition of the IEE Wiring Regulations, (BS.7671), and any relevant Local Authority bye-laws. 
 

This heater is fitted with a 3-core mains supply cable and should be permanently connected to 

the electricity supply via a double pole switch having 3 mm gap on each pole. 
 

A switched Fused Connection unit to BS.1363 Part 4 is a recommended mains supply connection 

accessory to ensure compliance with safety requirements applicable to fixed wiring installation. 

 
 
 
 

 

 