COSMOS DRIVER SERIES 3000 - USE AND MAINTENANCE MANUAL
◦
1
= topology in line with master on port 1
◦
2
= topology in line with master on port 2
As far as topology is concerned, please note that the optimal operation condition, to be taken into consideration during
the design phase, is the ring topology, because it guarantees the redundancy of master connection; in other words,
should one of the two Ethernet connections be lacking, the driver can continue working without interruptions. In this
case, the displayed topology will change from R to 1 or 2, depending on the port from where the driver receives the data
from the master.
If you select the topology in line, the driver will display 1 or 2, depending on the port from where the driver receives the
data from the master.
7.2.1.2
Controller FLxIO
XXX.X Hz
The device is generating the frequency XXX.X with the fieldbus active or in service
mode
7.2.1.3
Controller Sercos II
001 CP0
The first field consists of three figures and indicates the node address expressed in
decimal figures (001 in this example);
The second field, in normal conditions, indicates the communication phase (CP0÷CP4);
otherwise it displays EXX (XX indicates the error number)
7.2.1.4
Analogue controller
0 rpm
It indicates the rotation speed
7.2.1.5
Service controller
SERVICE
It indicates the service mode
7.2.1.6
Modbus TCP/IP controller
XXX.X Hz
The device is generating XXX.X frequency; the field bus is active or in service mode
7.2.2 Access level
By selecting the item LEVEL in the main menu and by pressing the key
,
you enter the function to insert the
password, in order to modify the parameter access level.
By means of the arrows, it is possible to enter the password, by confirming it by pressing the key
.
If the password is correct, the LCD will display a message of successful result and will display a new access level.
By pressing any key, the LCD will return to the main menu.
Here are the passwords available for the user:
Level
Password
1
-
2
PROGR
3
TARAT
4
>Reserved to SMITEC<
If no key is pressed for 5 minutes, the system will return to level 1 and it will not be possible to modify the data any
longer, unless you enter the password of the next level.
Ver. 1.07
Pag. 56
LEVEL[1]
PW XXXXX
LEVEL[3]
PW RIGHT