Installation
25
EN
Burner and nozzle characteristics table
Regulation of primary air
60 cm. hob
70 cm. hob
1 ULPG 2.75 kPa
AUX
SR
RR
R
Wok
Dual Wok
Nominal gas consumption (MJ/h)
4.8
6.0
9.5
12.5
15.0
12.5 + 3.5
Injector (1/100 mm)
60
68
85
95
105
95 + 50
2 NG 1.0 kPA
AUX
SR
RR
R
Wok
Dual Wok
Nominal gas consumption (MJ/h)
4.8
6.0
11.5
12.2
15.0
11.5 + 3.5
Injector (1/100 mm)
98
110
150
155
170
150 + 85
1 ULPG 2.75 kPa
AUX
SR
R
Wok
Primary air (mm)
2
2
2
4
2 NG 1.0 kPA
AUX
SR
R
Wok
Primary air (mm)
3
3
3.5
5
1 ULPG 2.75 kPa
AUX
SR
RR
Dual Wok
Primary air (mm)
2
2
2
4 + 10
2 NG 1.0 kPA
AUX
SR
RR
Dual Wok
Primary air (mm)
2
6
6
3 + 3
Содержание SRA964NGH