36
Instructions for the installer
12. ADAPTATION TO DIFFERENT TYPES OF GAS
BEFORE PERFORMING ANY OPERATIONS, SWITCH OFF THE POWER SUPPLY TO THE
APPLIANCE.
Appliance set for gas:
LPG G30/G31
pressure 28/37
mbar
(see label on product)
In the case of operation with other types of gas, the burner nozzles must be changed and the minimum
flame adjusted on the gas taps.
To change the nozzles, proceed as described in the following paragraphs.
12.1 Replacing the hob nozzles
1 Remove the pan stands, and remove all burner caps
and flame-spreader crowns to access the burner
casings.
2 Unscrew the nozzles using a 7 mm socket wrench.
3 Replace the burner nozzles according to the type of gas
to be used (see 12.3 Burner and nozzle characteristics
table).
4 Replace the burners in the correct position.
12.2 Arrangement of burners
Burner
Auxiliary
Semi-rapid
Rapid
Ultra-rapid
Содержание SIL68MA8