1.5 Burner and nozzle characteristics
table
To adjust the appliance for LP gas or to
return to Natural Gas use, refer to the charts
below.
• Connect the gas supply line to the unit
pressure regulator using a 1/2” flex gas
line connector between the manual
shutoff valve and the pressure regulator.
A metal flex line or fixed metal pipe must
be used to connect the gas to the
appliance. If a metal gas line cannot be
used, consult your local certified
electrician or local electric codes for
proper grounding.
• Check the supply line connections for
leaks using a soap solution or
noncorrosive leak detection fluid. Do not
use a flame of any sort.
Important notes for Gas Connection
• The appliance and its individual gas
shutoff valve must be disconnected from
the gas supply piping system during
pressure testing of the system at test
pressures in excess of 1/2 psi (3.5 kPa).
• The appliance must be isolated from the
gas supply piping system by turning off
its individual manual shut-off valve during
pressure testing of the gas supply piping
system at test pressures equal to or less
than 1/2 psi (3.5 kPa).
Final operations
• Completely fill out the Gas Conversion
label (part no. 92849A078) and attach
it to the rear or bottom of the appliance.
Do not cover any other labels with the
Gas Conversion label.
• Over time the gas taps may become
difficult to turn and get blocked. Clean
them internally and replace the
lubrication grease.
• Save the nozzles removed from the
appliance along with these instructions
for possible future use.
• For installation of the appliance at high
altitude, please consult your local gas
company for their recommendation on
the correct orifice sizes and any other
necessary adjustments that will provide
proper gas combustion at specified
altitudes.
Natural Gas
Rapid
Dual Flame
QT (BTU)
12000
18000
Injector Ø (mm)
1.52
1.80 + 0.75
QR (BTU)
750
750
LPG
Rapid
Dual Flame
QT (BTU)
12000
18000
Injector Ø (mm)
1.05
1.17 + 0.48
QR (BTU)
750
750
By-pass (mm)
45
55 + 30
Model
Total Rated Input (BTU)
RTU304GX (30”)
54000
RTU366GX (36”)
84000
NOTE
: Save the nozzles that were
removed from the appliance along
with these instructions for possible
future use.
NOTE
: Lubrication of the gas taps
should be performed by a
specialized technician.