![Smeg PX375AU Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/smeg/px375au/px375au_manual_1301772016.webp)
Installation
18
5 Installation
5.1 Minimum clearance to
combustible surface
Cooktop
A
200mm (Vertical combustible surface)
B
600mm (Overhead) measured form the
highest part of the highest burner and
750mm for an exhaust fan.
C
50mm (non-combustible surface)
D
20mm (benchtop)
X
(width)
& Y
(depth) see appliance
dimension within this manual.
Refer to AS/NZS 5601 (Protection of a
combustible surface) if the above minimum
clearances cannot be achieved.
Maximum height of the top of the pan
support with respect to the surface that
supports the appliance is 47mm.
5.2 Safety instructions
Veneers, adhesives or plastic coatings on
adjacent furniture should be temperature-
resistant (
>90°C
), otherwise they might
warp over time.
The minimum clearances must also be
respected for the edges of the cooktop on
the back as indicated in the mounting
illustrations.
The appliance connection point
shall be accessible with the
appliance installed.
Heat production during appliance
operation
Risk of fire
• Make sure that the cabinet material is
heat resistant.
• Check that the cabinet has the required
slots.
The minimum clearance between a
ventilation hood and the cooking
surface must be at least the
distance indicated in the ventilation
hood installation instructions.