Instructions for the Installer

6

3. POSITIONING THE COOKTOP AND LOCATION REQUIREMENTS

NOTE: 

 The following operation requires building and/or carpentry work and must therefore be carried

out by a competent technician.
Installation can be carried out on various material, such as masonry, metal, solid wood, plastic laminated
wood etc. As long as they are heat resistant (T = 90°C - 194° F).
Observe all governing codes and ordinances. Do not obstruct flow or combustion and ventilation air. 

-  It is the installer’s responsibility to comply with installations guidelines specified on the model/serial

rating plate. The model/serial rating plate is located on the underside of the cooktop burner box.

-  The cooktop should be installed in a location away from strong draft areas, such as windows, doors

and strong heating vents or fans.

-  All openings in the wall or floor where cooktops is to be installed must be sealed.

-  Cabinet opening dimensions that are shown must be used. Given dimensions are minimum

clearances.

-  Appliance should not be installed with an air curtain ventilation system that blows air downward

toward the appliance, unless the ventilation system and appliance have been designed, tested in
accordance with ANSI Z21.1 and listed by an independent testing laboratory for combination use.
This type of ventilation system may cause ignition and combustion problems with the gas cooking
appliance resulting in personal injury or unintended operation.

-  Grounded electrical supply is required. See “Electrical Requirements” section. Proper gas supply

connection must be available. See “Gas Supply Requirements” section

To prevent accidents or ruining the mobile components of the appliance, the following steps must be
taken before performing the procedures described below:

1 Remove all packaging parts (e.g. crate, carton, polystyrene and metal hooks). Do not eliminate this

manual as it is an integral part of the appliance and it should be kept handy for easy reference
whenever needed.

2 Temporarily remove all removable parts from the cooktop that could fall and cause personal injury or

damage to objects (burners, crowns and flame caps) during the attachment procedures These parts
must be refitted before using the appliance.

The measurements supplied in the tables referring to the figure below must be followed when attaching
the appliance to the support structure. 

Содержание PU64ES

Страница 1: ...OP AND LOCATION REQUIREMENTS 6 3 1 Gas supply requirements 8 3 2 Electrical requirements 9 4 INSTALLING THE COOKTOP 11 5 CHECKING OPERATION 14 6 WIRING DIAGRAMS 15 INSTRUCTIONS FOR THE INSTALLER these...

Страница 2: ...ernment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do...

Страница 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Страница 4: ...ws air downward toward the appliance unless the ventilation system and appliance have been designed tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination...

Страница 5: ...1 8 483 485 mm 8 1 4 210 mm 3 3 8 86 mm 1 7 16 36 mm 1 3 4 45 mm 27 1 2 700 mm 39 3 8 1000 mm 33 11 16 33 14 16 855 860 mm 19 1 8 19 5 16 485 490 mm 8 1 4 210 mm 4 7 16 112 mm 1 7 16 36 mm 1 3 4 45 mm...

Страница 6: ...must conform to American National Standards National Fuel Gas Code ANSI Z223 1 latest edition or CANI 13149 1 or 2 2 If local codes permit a flexible metal appliance connector with the new AGA or CSA...

Страница 7: ...tem by closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed...

Страница 8: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Страница 9: ...ply pressure for LP operation of the cooktop 1 Unscrew cap A on the pressure regulator 2 Turn it to the part where LP is printed 3 Re tighten it and lock the pins in the slots provided 4 There is an a...

Страница 10: ...the hole on the inner side of the gasket The diagram below shows the exact positions of the holes to be used for clamping the hob to the top by the brackets correctly NOTE Use all of the brackets sup...

Страница 11: ...s used be certain tubing is not kinked Use only pipes E conforming to standard regulations in force inserting gasket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas co...

Страница 12: ...found on the cooktop These procedures must be repeated for each burner on the cooktop CAUTION refit all flame caps in the same points from which they were removed In fact the flame cap positions canno...

Страница 13: ...quipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring e...

Страница 14: ...ith a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can...

Страница 15: ...ith a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring errors can...

Отзывы: