Installation
23
EN
5.5 Fixing using brackets
The figures below show the exact position
of the holes to correctly attach the cooktop
to the countertop using the brackets
provided (
A
)
Screw the fixing brackets (
A
) into the holes
on the sides of the bottom casing to
properly fasten the cooktop to the structure.
5.6 Gas connection
General information
This appliance is suitable for installation with
Natural Gas or ULPG (propane/butane).
Refer to “Burner and injector specifications
tables” paragraph for the relevant burner
pressure and appropriate injector sizes.
When the appliance is to be connected to
Natural Gas then the pressure regulator
supplied must be fitted to the gas inlet. A test
point (for checking the gas pressure) is
supplied either with the regulator or as a
separate fitting in the case of ULPG
(propane) appliances.
Do not attach the cooktop with
silicone sealant, as this would not
allow subsequent removal without
damaging the appliance.
Gas leak
Danger of explosion
• After carrying out any operation, check
that the tightening torque of gas
connections is between 10 Nm and
15 Nm.
• If required, use a pressure regulator that
complies with current regulations.
• At the end of the installation, check for
any leaks with a soapy solution, never
with a flame.
• Installation with flexible hose must be
carried out so that the length of the
piping does not exceed 1,2 metres
when fully extended; make sure that the
hoses do not come into contact with
moving parts and that they are not
crushed in any way.
• The hoses should not come into contact
with moving parts and should not be
crushed in any way.
• The settings for this domestic appliance
are shown on the gas setting label.