Installation
32
When the job is complete, the installer must
issue a certificate of conformity.
1
Extraction using a hood
2
Extraction without a hood
A
Single natural draught chimney
B
Single chimney with extractor fan
C
Directly outdoors with wall- or window-
mounted extractor fan
D
Directly outdoors through wall
Air
Combustion products
Extractor fan
5.2 Adaptation to different types of gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
taps.
Replacing nozzles
1. Remove the pan stands, burner caps and
flame-spreader crowns to access the
burner casings.
2. Replace the nozzles using a 7 mm
spanner according to the gas to be used
(see Burner and nozzle characteristics
tables).
3. Replace the burners in the correct
position.
Improper installation
Risk of malfunction
• In the case of conversion to
Town Gas
G110 – 8 mbar (category 1a)
, do not
use the burners provided, but request the
special
G110 burners kit
from our
Technical Assistance Service.