Instructions for the installer
40
2.
INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by
competent persons
.
Corgi gas installers are approved to work to safe and satisfactory
standards. All gas installation, servicing and repair work must be in
accordance with the gas safety regulations 1984 (installation and use) as
amended 1990.
It may be installed against walls one of which is higher than the worktop
surface, at least 50 mm from the side of the appliance, as shown in the
installation class drawings A and B. Wall units or extractor hoods installed
above the appliance's work-top must be at least 750 mm above it.
A
B
Slot
in
Free
standing
2.1
Electrical connection
Make sure that the power line voltage matches the specifications
indicated on the rating plate located inside the storage compartment.
This rating plate must never be removed.
The plug at the end of the power cable and the wall socket must be the
same type (conforming to regulations in force). Check that the power line
is adequately grounded. Do not use reducers, adapters or shunts.
If the appliance is connected to the power grid using a fixed connection,
fit the power line with an omnipolar circuit-breaker, in accordance with
the installation instructions, located in a readily accessible position near
the appliance.