Installation
82
Adjusting the minimum setting for LPG
Tighten the screw located at the side of the
valve rod clockwise all the way.
Lubricating the gas valves
Over time the gas valves can become
difficult to turn and get blocked. Clean them
internally and replace the lubrication
grease.
Dimensions
Position of gas and electrical connections.
Burner and nozzle characteristics table
Following adjustment to a gas
other than the one originally set in
the factory, replace the gas setting
label on the appliance with the
one corresponding to the new
type of gas. The label is inserted
inside the nozzle pack (where
fitted).
Lubrication of the gas valves be
performed by a specialised
technician.
A
48
B
738
C
124
D
97
NG 1.0 kPa
AUX
SR
R
DUAL int + ext
Nominal gas consumption (MJ/h)
3.9
7.5
12
15.2
Injector (1/100)
90
120
155
80 + 165
NG 2.75 kPa
AUX
SR
R
DUAL int. + ext.
Nominal gas consumption (MJ/h)
3.9
6.3
10.8
15.2
Injector (1/100)
54
68
88
46 + 94