SMD VARIO CONTROL START Скачать руководство пользователя страница 1

 

Starting up VARIO CONTROL START 

VARIO CONTROL START is 

operated 

with 230V-, 50Hz mains voltage. 

The temperature sensor supplied is connected to the corresponding input (see Inputs chapter) of the VARIO 
CONTROL START. The sensor is 

used to record the 

water 

temperature for aquarium management and 

the 

air 

temperature for terrarium management. 

When the VARIO CONTROL START is started up for the first time, 

Aqua

 appears, flashing, in the display. If 

VARIO CONTROL START is to be used for aquarium mode, confirm this input with the 

OK BUTTON. 

If it is to be used for terrarium mode, press the + 

BUTTON 

to select 

Tera

 and confirm your input with the 

OK 

BUTTON. 

(This setting can also be changed at any time in the 

SETUP 

sub-menu). 

 
After pressing the 

ESC BUTTON 

VARIO CONTROL START is in normal mode. 

If the operating mode setting is skipped by pressing the 

ESC BUTTON, 

VARIO CONTROL START 

is in aquarium mode! However, this setting is then not saved. 
Setting the time and other operating parameters is described in the 

VARIO CONTROL START Settings 

chapter. 
 
 

Power rating of the sockets: 

 
Socket 1: 

400W 

Socket 2: 

400W 

Socket 3: 

400W 

Socket 4 (continuous operation): 1200W 
 
 
 
 
 
 

3 Display and special symbols 

 
The display of the VARIO CONTROL START is shown in the 

following, 

special symbols 

are described. 

 

 

 

HUM  

Display / Humidity settings 

pH  

Display / pH value settings 

 

Display / Day settings 

 

Display / Night settings 

 Temperature 

display 

(°C) 

Содержание VARIO CONTROL START

Страница 1: ...ct Tera and confirm your input with the OK BUTTON This setting can also be changed at any time in the SETUP sub menu After pressing the ESC BUTTON VARIO CONTROL START is in normal mode If the operatin...

Страница 2: ...uttons Cancel current input or Return to last menu Confirm the selection Increase numerical value or next menu item Reduce numerical value 5 Arrangement of the sockets Socket 1 is always assigned to t...

Страница 3: ...ing this selection with the OK BUTTON leads to the TIME SETTING sub menu Confirm this selection by pressing the OK BUTTON The time hours flash Use the BUTTON and or the BUTTON to set the current time...

Страница 4: ...CAL4 The setpoint and hysteresis only appear if Socket 3 was configured for pH PH in the SETUP sub menu Display and use of the pH value control requires connection of a pH electrode available as an a...

Страница 5: ...u S1 is displayed Confirming this selection with the OK BUTTON leads to the SOCKET 2 sub menu Make the settings as described above If you want to skip an input use the BUTTON to switch to the next sel...

Страница 6: ...Fig 9 The first selection allows you to change the operating mode The current operating mode is displayed If this is to be changed confirm this by pressing the OK BUTTON Use the BUTTON or the BUTTON...

Страница 7: ...0 2 C Floor offset 2 C pH value Day 7 0 pH Hysteresis 0 2 pH Humidity Day 60 Night 60 Hysteresis 10 Metering period 5 seconds Max metering 30 minutes All timers 00 00 Sockets Socket 2 Timer Socket 3 T...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......

Страница 13: ......

Страница 14: ......

Страница 15: ......

Отзывы: