background image

 

Driver Revision:   1.01 

Document Revision:  1.A 

 

 

 

 

 

 

 

 

 

 

FieldServer  

FS-8700-122 PROFIBUS DP Master 

Driver Manual  

(Supplement to the FieldServer Instruction Manual)

 

 

 

 

 

 

 

 

 

 

APPLICABILITY & EFFECTIVITY 

Effective for all systems manufactured after May 2019. 

Содержание FieldServer FS-8700-122 PROFIBUS DP Master

Страница 1: ...n 1 01 Document Revision 1 A FieldServer FS 8700 122 PROFIBUS DP Master Driver Manual Supplement to the FieldServer Instruction Manual APPLICABILITY EFFECTIVITY Effective for all systems manufactured...

Страница 2: ...support needs related to the FieldServer product Sierra Monitor Corporation 1991 Tarob Court Milpitas CA 95035 Website www sierramonitor com U S Support Information 1 408 964 4443 1 800 727 4377 Email...

Страница 3: ...4 1 FieldServer 6 4 2 Data Arrays Descriptors 6 4 3 Client Side Connection Descriptors 7 4 4 Client Side Node Descriptors 7 4 5 Client Side Map Descriptors 8 4 5 1 FieldServer Related Map Descriptor P...

Страница 4: ...Y 125 This is the maximum number of PROFIBUS DP Slaves that can be connected to the FieldServer A maximum total of 1536 bytes can be transferred with all DP Slaves DRIVER SCOPE OF SUPPLY 2 1 Supplied...

Страница 5: ...GND from RS 485 side 6 5V BUS2 Isolated 5V from RS 485 side 7 Not connected 8 A Line Negative RxD TxD according to RS 485 specification 9 Not connected Only A line B line and Shield are used for most...

Страница 6: ...lient Side Nodes section and the data required from the Servers needs to be mapped in the Client Side Map Descriptors section Details on how to do this can be found below NOTE In the tables below indi...

Страница 7: ...tions Adapters Adapter Prof_DP 4 4 Client Side Node Descriptors Section Title Nodes Column Title Function Legal Values Node_Name Provide name for Node Up to 32 alphanumeric characters Node_ID Station...

Страница 8: ...ion Function of Client Map Descriptor Rdbc Wrbc 4 5 2 Driver Related Map Descriptor Parameters Column Title Function Legal Values Node_Name Name of Node from which to fetch data One of the node names...

Страница 9: ..._Descriptor_Name Data_Array_Name Data_Array_Offset Function Node_Name Word_Out Word_Out 0 Wrbc PDP_SLV003 Byte_Out Byte_Out 0 Wrbc PDP_SLV003 PROFIBUS_Data_Type Address Length Scan_Interval Word 0 50...

Страница 10: ...own in Section 3 Expand the PROFIBUS Master Tree select the ABM DPV device and drag it onto the Bus Configuration Screen This is the FieldServer PROFIBUS DP Master device Select Project New Expand the...

Страница 11: ...ress Continue adding all other Slaves and setting their PROFIBUS addresses Right click on the ABM DPV Master device and select Object Properties Set the Master Station Address to the same as the Syste...

Страница 12: ...ing other Slaves and adding modules for them as well NOTE Changing of Input and Output Addresses are not allowed All addresses must be contiguous for the PROFIBUS to work correctly Select Online Drive...

Страница 13: ...iver Manual Page 13 of 14 Choose Online Download configuration to install the embedded database in the FS B35 NOTE The FS B35 must be running with a valid configuration file before it will allow downl...

Страница 14: ...e Restarting FieldServer in 10 seconds Appendix A 1 2 Configuration Error Reported Ensure that the correct Map Descriptor function has been used Refer to Sections 4 5 2 and Section 4 7 Ensure that the...

Отзывы: