. Troubleshooting
If the product fails in any way, perform the following troubleshooting measures.
Failure phenomenon
Possible causes
Countermeasures
Vacuum
absorption
failure
Vacuum is not generated
Clogging by foreign matter or particles
See (1) and (2)
Vacuum pressure
decreased
Supply valve does not
operate
Decline in the
power supply
voltage
See (3) and (4)
Electrical wire
failure
See (4) and (5)
The supply pre
ssure exceeds
the operating
pressure range.
See (6)
Entry of oil mist
See (14)
Control failure
Simultaneous
energization
See (7)
Leakage voltage
See (8)
Incorrect
assembly
during maintenance
Mounting failure
of the gasket
See (9)
Insufficient supply pressure
See (6) and (10)
Fluctuation of
vacuum
pressure
Noise is generated intermitt
ently when air is exhausted
when adsorbing and
vacuum pressure slightly
fluctuates.
Vibration of fluid when vacuum pressure
is generated
See (11)
Air leakage
from vacuum
port
When using the manifold ty
pe, air flows from the vacu
um port of the stopped pro
duct.
Exhaust air flows to the vacuum port
See (12)
Vacuum
release failure
Release air is not output
Vacuum release flow adjusting needle is
fully closed
See (13)
Release valve does not operate
See (3), (4), (5), (6)
and (14)
Workpiece is not released
smoothly.
Adhesion of the workpiece and pad
See (15)
Control failure
Simultaneous
energization
See (7)
Leakage voltage
See (8)
Operation
failure of the
energy saving
switch
Vacuum is not held. Supply
valve chatters.
Vacuum leakage
See (16)