SMC Networks SX3000 Series Скачать руководство пользователя страница 1

Doc. no. SX3000-OMM0002-B 

 

 

 

 

 

 

 

 
 

PRODUCT NAME

 

 

5 Port Solenoid Valve 

 

MODEL / Series / Product Number

 

 

SX3000/5000/7000 Series 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SX3000 Series

Страница 1: ...Doc no SX3000 OMM0002 B PRODUCT NAME 5 Port Solenoid Valve MODEL Series Product Number SX3000 5000 7000 Series...

Страница 2: ...Precautions on Design Selection 4 5 Mounting 6 Piping 6 Wiring 6 Lubrication 7 Air Supply 7 Operating Environment 7 Maintenance 8 Specific Product Precautions 9 to 11 Valve Construction 12 13 Troubles...

Страница 3: ...e when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly oper...

Страница 4: ...duct 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year...

Страница 5: ...e In addition at the time of vacuum adsorption be sure to vacuum at all times Failure to do so may result in foreign matter sticking to the adsorption pad or air leakage causing the workpiece to drop...

Страница 6: ...d state may switch over see Figure 1 When installing a breaker circuit for the loading power supply consider using a solenoid valve with polarity with polarity protection diode or install a surge abso...

Страница 7: ...itable wrench to tighten the hexagonal portion of the body an additional 1 6 to 1 4 turn The reference value for the tightening torque is 1 to 1 5 N m Note Excessive tightening may damage the thread p...

Страница 8: ...ll an air filter Install an air filter upstream near the valve Select an air filter with a filtration size of 5 or smaller 3 Take measures to ensure air quality such as by installing an aftercooler ai...

Страница 9: ...o operate 3 Low frequency operation Valves should be operated at least once every 30 days to prevent malfunction Use caution regarding the air supply 4 Manual override When the manual override is oper...

Страница 10: ...port valve is required How to Use Plug Connector When attaching and detaching a connector first shut off the electric power and the air supply Also crimp the lead wires and sockets securely 1 Attachi...

Страница 11: ...ocket s hook with a stick having a thin tip approx 1 mm If the socket is used again spread the hook outward Common Connector Assembly Wiring When ordering common connector assemblies alone wiring shou...

Страница 12: ...be used again cut off the portion which has been chewed before reusing it If the chewed portion of the tube is used as is this can cause trouble such as air leakage or difficulty in removing the tube...

Страница 13: ...12 SX3000 OMM0002 B...

Страница 14: ...13 SX3000 OMM0002 B...

Страница 15: ...brasion spool ass y ring in the case of rubber seal Poor operation or adherence Excessive amount of lubricant Higher voltage or wrong coil used Faulty wiring Poor contact at contactor wire or connecti...

Страница 16: ...cation was suspended temporary Water splashed directely Strong impact was given Alien substance such as drain and particle got into Drain or garbage invaded a valve Reduce the amount of lubricant to t...

Страница 17: ...kyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 201...