Installing the Switch

3-4

3

2.

Mount the device in the rack, using four rack-mounting screws (not provided). 
Be sure to secure the lower rack-mounting screws first to prevent the brackets 
being bent by the weight of the switch.

Figure 3-3  Installing the Switch in a Rack

3.

If installing a single switch only, turn to “Connecting to a Power Source” at the 
end of this chapter.

4.

If installing multiple switches, mount them in the rack, one below the other, in 
any order.

Содержание SMC TigerSwitch 10/100 SMC6110L2

Страница 1: ...INSTALLATION GUIDE TigerSwitchTM 10 100 8 Port 10 100 Managed Switch plus 2 Gigabit Combo Ports SMC6110L2 ta...

Страница 2: ......

Страница 3: ...20 Mason Irvine CA 92618 Phone 949 679 8000 TigerSwitch 10 100 Installation Guide From SMC s Tiger line of feature rich workgroup LAN solutions January 2008 Pub 150200065200A E012008 AP R01...

Страница 4: ...ed by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2008 by SMC Networks Inc 20 Mason Irvine CA...

Страница 5: ...ved by the party responsible for compliance could void your authority to operate the equipment You may use unshielded twisted pair UTP for RJ 45 connections Category 3 or better for 10 Mbps connection...

Страница 6: ...fluctuation and flicker in low voltage supply system according to EN 61000 3 3 1995 Immunity Product family standard according to EN 55024 1998 Electrostatic Discharge according to EN 61000 4 2 1995...

Страница 7: ...er SELV Safety Extra Low Voltage conditions according to IEC 60950 The conditions are only maintained if the equipment to which it is connected also operates under SELV conditions France and Peru only...

Страница 8: ...lectrique au niveau de cette prise L appareil fonctionne une tension extr mement basse de s curit qui est conforme la norme IEC 60950 Ces conditions ne sont maintenues que si l quipement auquel il est...

Страница 9: ...ts kann nur durch Herausziehen des Ger tenetzkabels aus der Netzsteckdose unterbrochen werden Der Betrieb dieses Ger ts erfolgt unter den SELV Bedingungen Sicherheitskleinstspannung gem IEC 60950 Dies...

Страница 10: ...rectly at a transmit port when it is powered on Caution Wear an anti static wrist strap or take other suitable measures to prevent electrostatic discharge when handling this equipment Caution Do not p...

Страница 11: ...reusable waste content Design of products to maximize recyclables at the end of the product s life span Continual monitoring of safety standards End of Product Life Span This product is manufactured...

Страница 12: ...viii...

Страница 13: ...es important information or calls your attention to related features or instructions Caution Alerts you to a potential hazard that could cause loss of data or damage the system or equipment Warning Al...

Страница 14: ...x...

Страница 15: ...ent 1 5 Chapter 2 Network Planning 2 1 Introduction to Switching 2 1 Application Examples 2 2 Collapsed Backbone 2 2 Network Edge Deployment 2 3 Application Notes 2 4 Chapter 3 Installing the Switch 3...

Страница 16: ...main 4 6 10 Mbps Ethernet Collision Domain 4 6 Cable Labeling and Connection Records 4 7 Appendix A Troubleshooting A 1 Diagnosing Switch Indicators A 1 Power and Cooling Problems A 1 Installation A 1...

Страница 17: ...X Gigabit Ethernet Cable Lengths 4 6 Table 4 3 Maximum 1000BASE LX Gigabit Ethernet Cable Length 4 6 Table 4 4 Maximum 1000BASE LH Gigabit Ethernet Cable Length 4 6 Table 4 5 Maximum Fast Ethernet Cab...

Страница 18: ...3 3 Installing the Switch in a Rack 3 4 Figure 3 4 Attaching the Adhesive Feet 3 5 Figure 3 5 Inserting an SFP Transceiver into a Slot 3 5 Figure 3 6 Power Socket 3 6 Figure 3 7 Serial Port DB 9 DTE...

Страница 19: ...0L2 provides a broad range of powerful features for Layer 2 switching delivering reliability and consistent performance for your network traffic It brings order to poorly performing networks by segreg...

Страница 20: ...n band using SNMP or RMON Groups 1 2 3 9 protocols It also has an RS 232 serial port DB 9 connector on the rear panel for out of band management A PC may be connected to this port for configuration an...

Страница 21: ...on and network troubleshooting The LEDs which are located on the front panel for easy viewing are shown below and described in the following tables Figure 1 2 Port LEDs Table 1 1 Port Status LEDs LED...

Страница 22: ...manually RJ 45 10 100BASE TX ports with auto MDI MDI X Unshielded UTP cable supported on all RJ 45 ports Category 3 or better for 10 Mbps connections Category 5 or better for 100 Mbps connections and...

Страница 23: ...idth of up to 5 6 Gbps Switching table with a total of 8K MAC address entries Provides store and forward switching Wire speed filtering and forwarding Supports flow control using back pressure for hal...

Страница 24: ...Introduction 1 6 1...

Страница 25: ...ice experiencing congestion server power user or hub can be attached directly to a switched port And by using full duplex mode the bandwidth of the dedicated segment can be doubled to maximize through...

Страница 26: ...tion adding direct full duplex connections to workstations or servers When the time comes for further expansion just connect to another hub or switch using one of the Fast Ethernet ports built into th...

Страница 27: ...ridged node that is ideal for a meeting room environment Zero noise makes the switch inobtrusive for such a setting In the figure below the SMC6110L2 is connected to a central wiring closet via a 1000...

Страница 28: ...s it is actually required to solve a problem Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub 3 As a general rule the length of fiber optic c...

Страница 29: ...at the unit is connected to a separate grounded power outlet that provides 100 to 240 VAC 50 to 60 Hz is within 2 m 6 6 feet of each device and is powered from an independent circuit breaker As with a...

Страница 30: ...sive foot pads Bracket Mounting Kit containing two brackets and eight screws for attaching the brackets to the switch Power Cord either US Continental Europe or UK RS 232 console cable This Installati...

Страница 31: ...the rack environment temperature is within the specified operating temperature range See page C 1 Mechanical Loading Do not place any equipment on top of a rack mounted unit Circuit Overloading Be su...

Страница 32: ...wer rack mounting screws first to prevent the brackets being bent by the weight of the switch Figure 3 3 Installing the Switch in a Rack 3 If installing a single switch only turn to Connecting to a Po...

Страница 33: ...power source making sure there are at least two inches of space on all sides for proper air flow 3 If installing a single switch only go to Connecting to a Power Source at the end of this chapter 4 If...

Страница 34: ...not need to be powered off before installing or removing a transceiver However always first disconnect the network cable before removing a transceiver Note SFP transceivers are not provided in the swi...

Страница 35: ...onnect to the serial port are provided in the following table Figure 3 7 Serial Port DB 9 DTE Pin Out Wiring Map for Serial Cable The serial port s configuration requirements are as follows Default Ba...

Страница 36: ...Installing the Switch 3 8 3...

Страница 37: ...h ends Use Category 5 5e or 6 cable for 1000BASE T connections Category 5 or better for 100BASE TX connections and Category 3 or better for 10BASE T connections Cabling Guidelines The RJ 45 ports on t...

Страница 38: ...actually required to solve a problem Otherwise back pressure jamming signals may degrade overall performance for the segment attached to the hub 3 As each connection is made the Link LED on the switc...

Страница 39: ...s 4 3 4 3 Label the cables to simplify future troubleshooting See Cable Labeling and Connection Records on page 4 7 Figure 4 2 Network Wiring Connections Equipment Rack side view Switch Patch Panel Pu...

Страница 40: ...han the recommended maximum operational temperature of the product You must also use an approved Laser Class 1 SFP transceiver Hinweis Bei der Wahl eines Glasfasertransceivers mu f r die Beurteilung d...

Страница 41: ...ecause switches break up the path for connected devices into separate collision domains you should not include the switch or connected cabling in your calculations for cascade length involving other d...

Страница 42: ...imode fiber 400 MHz km 2 500 m 7 1641 ft LC 500 MHz km 2 550 m 7 1805 ft LC Table 4 3 Maximum 1000BASE LX Gigabit Ethernet Cable Length Fiber Size Fiber Bandwidth Maximum Cable Length Connector 9 125...

Страница 43: ...rly label the opposing ends of each cable Using your building s floor plans draw a map of the location of all network connected equipment For each piece of equipment identify the devices to which it i...

Страница 44: ...Making Network Connections 4 8 4...

Страница 45: ...nment where you are sure that all the other components are functioning properly Table A 1 Troubleshooting Chart Symptom Action Power LED is Off Check connections between the switch the power cord and...

Страница 46: ...link to the management agent check to see if you have a valid network connection Then verify that you entered the correct IP address Also be sure the port through which you are connecting to the swit...

Страница 47: ...mbered Be sure to hold the connectors in the same orientation when attaching the wires to the pins Figure B 1 RJ 45 Connector Pin Numbers 10BASE T 100BASE TX Pin Assignments Use unshielded twisted pai...

Страница 48: ...net Figure B 2 Straight through Wiring Table B 1 10 100BASE TX MDI and MDI X Port Pinouts Pin MDI Signal Name MDI X Signal Name 1 Transmit Data plus TD Receive Data plus RD 2 Transmit Data minus TD Re...

Страница 49: ...ort pinouts These ports require that all four pairs of wires be connected Note that for 1000BASE T operation all four pairs of wires are used for both transmit and receive Use 100 ohm Category 5 5e or...

Страница 50: ...erformance Category 5e or Category 6 cables 2 Reduce the number of connectors used in the link 3 Reconnect some of the connectors in the link Fiber Standards The current TIA Telecommunications Industr...

Страница 51: ...UTP cable Category 5 or better 1000BASE T RJ 45 100 ohm UTP or STP cable Category 5 5e or 6 Maximum Cable Length 100 m 328 ft Buffer Architecture 2 Mbits Aggregate Bandwidth 5 6 Gbps Switching Databas...

Страница 52: ...atts maximum Maximum Current 0 4 A 100 VAC 0 2 A 240 VAC Switch Features Forwarding Mode Store and forward Throughput Wire speed Flow Control Full Duplex IEEE 802 3x Half Duplex Back pressure Manageme...

Страница 53: ...col IEEE 802 1D Spanning Tree Protocol IEEE 802 1w Rapid Spanning Tree Protocol ISO IEC 8802 3 Compliances Emissions Industry Canada Class A EN55022 CISPR 22 Class A EN 61000 3 2 3 FCC Class A VCCI Cl...

Страница 54: ...Specifications C 4 C...

Страница 55: ...SMC6110L2 8 port 10 100 Managed Switch with 2 Gigabit Combo ports SMC1GSFP SX Single port 1000BASE SX Small Form Pluggable SFP mini GBIC transceiver SMC1GSFP LX Single port 1000BASE LX Small Form Plu...

Страница 56: ...Ordering Information D 2 D...

Страница 57: ...or long haul Gigabit Ethernet over two strands of 9 125 micron core fiber cable 1000BASE SX IEEE 802 3z specification for Gigabit Ethernet over two strands of 50 125 or 62 5 125 micron core fiber cabl...

Страница 58: ...or integration into the OSI model and extends the physical layer and media with repeaters and implementations that operate on fiber thin coax and twisted pair cable Fast Ethernet A 100 Mbps network co...

Страница 59: ...computer and support devices Media Access Control MAC A portion of the networking protocol that governs access to the transmission medium facilitating the exchange of data between network nodes MIB A...

Страница 60: ...ol suite that includes TCP as the primary transport protocol and IP as the network layer protocol UTP Unshielded twisted pair cable Virtual LAN VLAN A Virtual LAN is a collection of network nodes that...

Страница 61: ...4 6 cleaning fiber terminators 4 4 compliances EMC C 3 safety C 3 connectivity rules 10 Mbps 4 6 100 Mbps 4 6 1000 Mbps 4 6 console port pin assignments 3 7 contents of package 3 2 cooling problems A...

Страница 62: ...connecting to 4 1 4 4 power connecting to 3 7 problems troubleshooting A 1 R rack mounting 3 3 rear panel of switch 1 1 rear panel receptacles 1 4 RJ 45 port 1 2 1 3 connections 4 1 pinouts B 3 RMON...

Страница 63: ...Index Index 3 V VLANS tagging 2 5 W web based management 1 2...

Страница 64: ...Index Index 4...

Страница 65: ......

Страница 66: ...UTSCH Technischer Support und weitere Information unter www smc com SPANISH En www smc com Ud podr encontrar la informaci n relativa a servicios de soporte t cnico DUTCH Technische ondersteuningsinfor...

Отзывы: