![SMC Networks PSE550 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/smc-networks/pse550/pse550_instruction-manual_1298882001.webp)
PSE550-TF2Z042EN
Page 1 of 2
Instruction Manual
Low Differential Pressure Sensor
PSE550
The intended use of the pressure sensor is to measure the pressure of
fluids and provide an analogue output signal.
1 Safety Instructions
These safety instructions are intended to prevent hazardous situations
and/or equipment damage. These instructions indicate the level of
potential hazard with the labels of “Caution,” “Warning” or “Danger.”
They are all important notes for safety and must be followed in addition
to International Standards (ISO/IEC)
*1)
, and other safety regulations.
*1)
ISO 4414: Pneumatic fluid power - General rules relating to systems.
ISO 4413: Hydraulic fluid power - General rules relating to systems.
IEC 60204-1: Safety of machinery - Electrical equipment of
machines. (Part 1: General requirements)
ISO 10218-1: Manipulating industrial robots –Safety, etc.
•
Refer to the product catalogue, operation manual and handling
precautions for SMC products for additional information.
•
Keep this manual in a safe place for future reference.
•
To ensure safety of personnel and equipment the safety instructions
in this manual must be observed, along with other relevant safety
practices.
Caution
Caution indicates a hazard with a low level of risk
which, if not avoided, could result in minor or
moderate injury.
Warning
Warning indicates a hazard with a medium level
of risk which, if not avoided, could result in death
or serious injury.
Danger
Danger indicates a hazard with a high level of risk
which, if not avoided, will result in death or
serious injury.
Warning
•
Ensure compliance with relevant safety laws and standards.
All work must be carried out in a safe manner by a qualified person in
compliance with applicable national regulations.
2 Specifications
2.1 General Specifications
2.2 Cable Specification
Cable details
3 cores
2 cores
Wire cross section
0.15 mm
2
Insulator O/D
0.9 mm
Sheath material
Oil resistant heavy-duty vinyl chloride
Sheath outside
dimension
2.7 x 3.2 mm
Cable Length
3 m
2.3 Specification when combined with PSE300 monitor
Setting pressure range
Differential pressure range
Rated pressure range
0 to 2 kPa
Set resolution
0.01 kPa
Switch
Repeatability
±0.4% F.S.
Analogue
output
Linearity
±0.7% F.S.
Accuracy (Display)
±1.5% F.S.
Accuracy (Operating temperature)
±1.5% F.S. ±1 digit
Temperature characteristic
±3.5% F.S. (25
o
C standard)
Warning
•
Special products (-X) might have specifications which are different
from those shown in this section. Contact SMC for specific drawings.
2 Specifications (continued)
2.4 Analogue Output
3 Installation
Warning
Do not install the product unless the safety instructions have been read
and understood.
3.1 Piping
Caution
•
Before piping make sure to clean up chips, cutting oil, dust etc.
•
Install the piping correctly in a safe place away from water and dust.
•
Cut the air tube perpendicularly.
•
Grip the air tube and insert it into the resin pipe firmly by 8 mm or
more from the end of the resin piping. The pulling force necessary for
the piping inserted by 8 mm or more is approximate 25 N.
•
Insert the air tube for low pressure to piping marked ‘Lo’ and the air
tube for high pressure to piping marked ‘Hi’.
3.2 Environment
Warning
•
Do not use in an environment where corrosive gases, chemicals, salt
water or steam are present.
•
Do not use in an explosive atmosphere.
•
Do not expose to direct sunlight. Use a suitable protective cover.
•
Do not install in a location subject to vibration or impact in excess of
the product’s specifications.
•
Do not mount in a location exposed to radiant heat that would result
in temperatures in excess of the product’s specifications.
4 Wiring
4.1 Internal circuit and wiring
•
Output specification
PSE550
Voltage output: 1 to 5 V
Output impedance: Approx. 1 kΩ
PSE550-28
Current output: 4 to 20 mA
Allowable load impedance: 500
Ω
or less (at 24 VDC)
100
Ω
or less (at 12 VDC)
4.2 Attaching a sensor connector to the lead wire
•
The sensor wire sheath should be stripped as shown in the figure.
•
Do not cut the insulation.
•
The corresponding wire colour shown in the table should be pushed
fully into the correct pin number marked on the sensor connector.
Pin No.
Wire colour
PSE550
PSE550-28
1
Brown (DC+)
Brown (LINE(+))
2
N.C.
N.C.
3
Blue (DC-)
N.C.
4
Black (IN: 1 to 5 V)
Blue (LINE(-))
•
Check that the above preparation has been performed correctly, then
press part A by hand to make a temporary connection.
•
Press part A fully home using a suitable tool.
•
The sensor connectors cannot be re-used once they have been
pressed fully closed. If connection failure or incorrect wiring occurs a
new sensor connector must be used.
•
When connecting the sensor to a PSE300 series monitor, use the
connector for sensor lead wire (ZS-28-C) or an e-Con* connector
from the table below.
Maker
Model No.
Sumitomo 3M
37104-3101-000FL
Tyco Electronics
1-1473562-4
OMRON
XN2A-1430
* Refer to the manufacturers e-Con connector catalogue.
ORIGINAL INSTRUCTIONS
Air tubing (4 mm I.D.)
Model
PSE550
PSE550-28
Rated Pressure range
0 to 2 kPa
Operating pressure
range
-50 to 50 kPa
Extended Analogue
output range
-0.2 to 0 kPa
-
Withstand pressure
65 kPa
Applicable fluid
Air, inert gases and incombustible gases
Power supply
voltage
12 to 24 VDC ±10%
(with 10% max. voltage ripple)
Current consumption
15 mA or less
Analogue output
specification
Voltage output:
1 to 5 VDC
(rated pressure
range)
0.6 to 1 VDC
(extended analogue
output range)
Output impedance:
a
pprox. 1 kΩ
Current output:
4 to 20 mA
(rated differential
pressure range)
Maximum allowable
load impedance:
500 Ω
(at 24 VDC)
100 Ω (at 12 VDC)
Accuracy (at 25°C)
±1% F.S. (rated pressure range)
±3% F.S. (extended analogue output range)
Linearity
±0.5% F.S.
Repeatability
±0.3% F.S.
Indicator light
Orange LED is ON when energized
E
nv
ir
on
m
e
nt
al
Enclosure
IP40
Ambient
temperature
Operation: 0 to 50°C
Storage: -20 to 70°C
(no condensation or freezing)
Ambient humidity
Operation, Storage: 35 to 85% RH
(no condensation)
Withstand
voltage
1000 VAC or more (50/60 Hz), 1 minute
(between lead block and case)
Insulation
resistance
50
MΩ or more at 500 VDC
(between lead block and case)
Temperature
characteristics
±3% F.S. (at 25°C)
Port size
ø4.8 (ø4.4 at the end) resin piping
(suitable for ø4 I.D. air tubing)
Material of parts in
contact with fluid
Resin pipe: Nylon,
Piston area of sensor: Silicon
Weight with cable
75 g
Weight without cable
35 g
Analogue
Output [V]
Differential
Pressure (kPa)
PSE550: 1 to 5 VDC
Analogue
Output [V]
PSE550-28: 4 to 20 mA
Differential