-14-
No. PF
※※
-OMK0004-F
Mounting and Installation
■
Installation
When the product is installed in a vertical direction, a natural convection is generated due to the sensor
characteristics around the zero flow range, so there is a possibility that an error up to approximately 3%F.S.
might be generated. Install the product taking this into consideration.
Direct mounting
Install the product using the M3 screws (2 pcs.).
Bracket mounting
Mount the bracket using the mounting screws (M3 x 15 L) supplied.
The required tightening torque is 0.32±0.02 Nm.
Install the product (with bracket) using the M4 screws (2 pcs. or 4 pcs.).
Bracket thickness is approximately 1 mm.
Refer to the dimension drawing of the bracket (page
) for mounting hole dimensions.