background image

-13- 

 

No.PF

※※

-OMG0006-F

 

 

Mounting and Installation 

Installation 

Never mount the product in a location that will be used as a foothold. 

 
 

Installing

 

Install the product (with bracket) using the M4 screws (4 pcs.). 

The required tightening torque is 0.69 to 0.83 Nm.

 

Tightening with excessive force may damage the product.

 

Refer to the dimension drawing (pag

22

) for mounting hole dimensions.

 

 

 

Содержание PF2D5 Series

Страница 1: ...No PF OMG0006 F PRODUCT NAME Digital Flow Switch Remote type sensor unit MODEL Series Product Number PF2D5 ...

Страница 2: ...11 Definition and terminology 12 Mounting and Installation 13 Installation 13 Piping 14 Wiring 15 Troubleshooting 17 Cross reference for troubleshooting 17 Specification 18 Specifications 18 Material of parts in contact with fluid and fluids compatibility checklist 19 Characteristics data 20 Dimensions 22 Made to Order 24 ...

Страница 3: ... equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to remo...

Страница 4: ... the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the use of the v...

Страница 5: ...ify the specifications before use Do not operate in an atmosphere containing flammable explosive or corrosive gas Fire explosion or corrosion can result This product is not designed to be explosion proof Do not use the product for flammable or highly permeable fluids Fire explosion corrosion or damage can result Refer to the Material Safety Data Sheet and confirm safety before use Do not use the p...

Страница 6: ... can result Insufficient supply voltage may not drive a load due to a voltage drop inside the product Verify the operating voltage of the load before use Do not exceed the specified maximum allowable load Otherwise it can cause damage or shorten the lifetime of the product Applicable fluids are DI water and fluids which do not corrode or erode fluoropolymer Fluid viscosity should be 3 mPa s 3 cP o...

Страница 7: ...UT side is opened or flow rate is excessive cavitations may be generated which may result in improper measurement As a measure against this it is possible to reduce the cavitations by increasing the fluid pressure Take action such as mounting an orifice on the OUT side of the product and confirm that there is no malfunction before handling If the orifice of the OUT side is fully closed to operate ...

Страница 8: ...wer is on Otherwise damage to the internal parts can result causing malfunction Do not route wires and cables together with power or high voltage cables Otherwise the product can malfunction due to interference or noise and surge voltage from power and high voltage cables to the signal line Route the wires piping of the product separately from power or high voltage cables Confirm proper insulation...

Страница 9: ...n areas that are exposed to vibration or impact Otherwise failure or malfunction can result Do not use the product in the presence of a magnetic field This may lead to the malfunction of the product Prevent foreign matter such as wire debris from entering the product Otherwise failure or malfunction can result Do not use the product in areas subject to large temperature cycle Heating cooling cycle...

Страница 10: ...er output frequency at excess flow state Do not use the product within the excess flow area in the chart below Maintenance Perform regular maintenance and inspections There is a risk of unexpected malfunction of components due to the malfunction of equipment and machinery Turn off the power supply stop the fluid and check the safety before performing any maintenance There is a risk of unexpected m...

Страница 11: ... OMG0006 F Model indication and How to Order Accessories Part number If an accessory is required separately order using the following part numbers Part number Description Qty Weight ZS 28 CA 2 Connector 1 pc 2 g ...

Страница 12: ...Item Description Body The body of the product Piping port Tube Connected to the fluid inlet at IN side and to the fluid outlet at OUT side Mounting hole Used to mount the product Lead wire Lead wire to supply power and transmit output signals 3 m ...

Страница 13: ...ity therefore it is possible to calculate the fluid flow rate by measuring the Karman vortex frequency O Operating humidity range The ambient humidity range within which the product will meet all published specifications Operating temperature range The ambient temperature range within which the product will meet all published specifications P Part in contact with fluid A part that comes into physi...

Страница 14: ... a location that will be used as a foothold Installing Install the product with bracket using the M4 screws 4 pcs The required tightening torque is 0 69 to 0 83 Nm Tightening with excessive force may damage the product Refer to the dimension drawing page 22 for mounting hole dimensions ...

Страница 15: ...ing suitable fittings Mount the product so that the fluid direction is the same as the arrow indicated on the product The piping on the IN side must have a straight section of piping whose length is 8 times the piping diameter or more Avoid sudden changes in the piping size on the IN side of the product Bubbles may be generated depending on the piping design Refer to an example of recommended pipi...

Страница 16: ...by using a series power supply instead of a switch mode power supply Lead wire Colour Content Black Output for PF2D3 Brown DC Blue DC White Analogue output Connecting the wiring Attaching the sensor connector to the lead wire When the product connects to the PF2D2 Refer to the PF2D2 operation manual for details of the sensor connector pin numbers Strip the lead wire as shown Do not cut the insulat...

Страница 17: ...fer to the PF2D3 or PF2D2 operation manual for details of the flow monitors 2 Load indicates analogue input equipment such as a voltmeter Output for PF2D3 Analogue 4 to 20 mA type PF2D5 2 Analogue output 4 to 20 mA Load impedance 300 Ω 12 VDC 600 Ω 24 VDC 1 Refer to the PF2D3 operation manual for details of the flow monitor 3 Load indicates analogue input equipment such as an ammeter ...

Страница 18: ...robable cause Recommended action Output There is no output Wiring failure Correct the wiring Output is unstable Foreign matter inside Set up filter at IN side of product If there is foreign matter stuck to the mesh remove it completely taking care not to damage the product Piping is connected in the wrong direction Install with the mounting direction corresponding to the flow direction arrow indic...

Страница 19: ...voltage 12 to 24 VDC 10 Power consumption No load 20 mA or less Environment Enclosure IP65 Operating temperature range Operation 0 to 50 C Storage 25 to 85 C no condensation or freezing Operating humidity range Operation Storage 35 to 85 R H no condensation Temperature characteristics 5 F S max 0 to 50 C 25 C reference Withstand voltage 1000 VAC for 1 minute between the external terminals and case...

Страница 20: ...oncentration 30 or less Table symbol Can be used Can be used under certain condition x Cannot be used 1 The material and fluid compatibility check list provides reference value as a guide only 2 It is possible that some fluids are permeable on the type of fluid its density and temperature Any permeated fluid may affect the products life Thus when using these fluids type verity the fluid in advance...

Страница 21: ... 20 No PF OMG0006 F Characteristics data Flow characteristics pressure loss PF2D504 PF2D520 PF2D540 ...

Страница 22: ...06 F Analogue output A B C Voltage output 1 V 1 5 V 5 V Current output 4 mA 6 mA 20 mA Model Rated flow range L min Min Max PF2D504 0 4 4 PF2D520 1 8 20 PF2D540 4 40 Fluid temperature and pressure PF2D504 520 PF2D540 ...

Страница 23: ... 22 No PF OMG0006 F Dimensions in mm PF2D504 520 Model A PF2D504 9 53 PF2D520 12 7 ...

Страница 24: ... 23 No PF OMG0006 F PF2D540 ...

Страница 25: ... 24 No PF OMG0006 F Made to Order Model Indication and How to Order Refer to page 10 for details of model indication and how to order ...

Страница 26: ...Union elbow Panel mount union Union tee Union Specifications Model PF2D504 PF2D520 PF2D540 Weigh included lead wire 11 max 20 g 13 max 30 g 19 max 65 g 1113 max 25 g 1319 max 45 g 1925 max 90 g 1311 max 25 g 1913 max 45 g 2519 max 90 g 13 max 30 g 19 max 65 g 25 max 115 g Other specifications are equal to standard product ...

Страница 27: ... 26 No PF OMG0006 F Dimensions in mm PF2D504S 11 1S Tubing size A Tubing size B 3 27 5 mm 3 23 mm 4 33 mm 4 39 mm ...

Страница 28: ... 27 No PF OMG0006 F PF2D520S 13 1S Tubing size A Tubing size B 4 33 mm 4 23 mm 5 39 mm 5 28 mm ...

Страница 29: ... 28 No PF OMG0006 F PF2D540S 19 1S Tubing size A Tubing size B 5 39 mm 5 39 mm 6 49 5 mm 6 49 mm ...

Страница 30: ...ntents revised in several places E Contents revised in several places September 2017 F Contents revised in several places July 2018 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2011 2018 SMC Corporation All Rights Rese...

Отзывы: