4 Operation
4-23
Pn20E
Electronic Gear Ratio (Numerator)
Position
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 1073741824
1
4
After restart
Setup
Pn210
Electronic Gear Ratio (Denominator)
Position
Classification
Setting Range
Setting Unit
Factory Setting
When Enabled
1 to 1073741824
1
1
After restart
Setup
4.4.3 Electronic Gear
The electronic gear enables the workpiece travel distance per reference unit input from the host PC or PLC...etc.
The minimum unit of the position data moving a load is called a reference unit.
(1) Electronic Gear Ratio
Set the electronic gear ratio using Pn20E and Pn210.
If the gear ratio of the servomotor and the load shaft is given as n/m where m is the rotation of the
servomotor and n is the rotation of the load shaft,
Содержание LECYU Series