![SMC Networks LECSN-T Series Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/smc-networks/lecsn-t-series/lecsn-t-series_operation-manual_1299644021.webp)
-20-
4.8.1 Parameter reading
If you read the parameters of the driver to the software, please do the “read” operation.
①
From the View menu bar "parameter (A)" - please click on the "parameter setting (P)". "Parameter
Settings" screen will display.
②
Please click on the “Read".
4.8.2 Parameter setting (Ex. Control mode change)
The following is an example of changing the Control mode (Pr.PA01).
①
Set the parameters of Pr.PA01 to “0001” in “Basic” tab.
②
Click on the “Single Axis Write” button.
③
Turn the power OFF and ON again. The Parameter is then enabled.
When changing of each parameter, note the following points.
Note1) Some of the various parameters, there is "Enable once on again turning the power OFF after
setting". (If you do not the power to OFF, it does not reflect the data in the driver.)
Note2) “Selected Items Write”: It writes the parameter values of the corresponding frame to the driver.
“Single Axis Write”: It writes all of the parameters to the driver.
Note3) Do not change “For manufacturer setting” parameters.
If you change by these by mistake,
it may cause the driver to not work properly.
②
①
②