![SMC Networks LECSB Series Скачать руководство пользователя страница 333](http://html1.mh-extra.com/html/smc-networks/lecsb-series/lecsb-series_operation-manual_1299641333.webp)
13 - 31
13. COMMUNICATION FUNCTION
(b) Temporary stop/restart/remaining distance clear
Send the following command, data No. and data during positioning operation to make deceleration to a
stop.
Command
Data No.
Data
[A][0]
[4][1]
STOP
Send the following command, data No. and data during a temporary stop to make a restart.
Command
Data No.
(Note) Data
[A][0]
[4][1]
GO
Note.
indicates a blank.
Send the following command, data No. and data during a temporary stop to stop positioning operation
and erase the remaining travel distance.
Command
Data No.
(Note) Data
[A][0]
[4][1]
CLR
Note.
indicates a blank.
13.5.9 Output signal pin ON/OFF output signal (DO) forced output
In the test operation mode, the output signal pins can be turned on/off independently of the servo status.
Using command [9][0], disable the output signals in advance.
(1) Choosing DO forced output in test operation mode
Transmit command [8][B]
data No.[0][0]
data "0004" to choose DO forced output.
0 0
Selection of test operation mode
4: DO forced output (output signal forced output)
0 4
(2) External output signal ON/OFF
Transmit the following communication commands.
Command
Data No.
Setting data
[9][2]
[A][0]
See below.
Command of each bit is sent to the slave station in hexadecimal.
b31
b0
0: OFF
1: ON
b1
bit
CN1 connector pin
bit
CN1 connector pin
bit
CN1 connector pin
bit
CN1 connector pin
0
49
8
16
24
1
24
9
17
25
2
23
10
18
26
3
25
11
19
27
4
22
12
20
28
5
48
13
21
29
6
33
14
22
30
7
15
23
31