
- 54 -
10.4
Initial setting value of LEY series
Initial setting value of LEY series.
Refer to the table below for initial setting of Return to origin, jog and inching.
Common for all series of LEY
Direction
Side to be retracted
speed [mm/s]
20
Return to home
origin
acceleration [mm/s
2
] 1000
speed [mm/s]
10
Jog
acceleration [mm/s
2
] 1000
Inching Distance[mm]
1
Refer to the table below for the set value for 3 levels of pushing force and the pushing speed. Pushing
speed is fixed.
LEY16 LEY25 LEY32
A B C A B C A B C
Low 14 27 51 63 126 232 80 156 296
Middle 26 50.5 96 92.5 182 342 134.5 263 501.5
Pushing
force [N]
High
38 74 141 122 238 452 189 370 707
Pushing
speed
[mm/s] 15 8 4 18 9 5 24 12 6
*Pushing force accuracy is ±20%F.S. Refer to the operation manual of the actuator for details.
Refer to the table below for the speed and the acceleration table of the LEY series.
LEY16A LEY16B LEY16C
speed
[mm/s]
acceleration
[mm/s
2
]
speed
[mm/s]
acceleration
[mm/s
2
]
speed
[mm/s]
acceleration
[mm/s
2
]
0 15
200
8
200
4 200
1 20
300
10
300
6 300
2 30
400
15
400
8 400
3 40
500
20
500
10 500
4 50
600
25
600
13 600
5 60
700
30
700
15 700
6 80
800
40
800
20 800
7 100
900
50
900
25 900
8 150
1000
75
1000
38 1000
9 200
1200
100
1200
50 1200
10 250
1400
125
1400
63 1400
11 300
1600
150
1600
75 1600
12 350
1800
175
1800
88 1800
13 400
2000
200
2000
100 2000
14 450
2500
225
2500
113 2500
15 500
3000
250
3000
125 3000