7.2 Setting parameters
In manual mode, it is possible to set parameters when necessary.
Example. Change the jog speed level from "1" (default condition) to "3"
(1)Switch the controller mode switch
○
e to manual mode (M).
(Example. "4" (Default value of position switch)
(2)Press the Forward button
○
i and Reverse
button
○
j simultaneously for 3 sec and the
power supply LED
○
a will flash.
(
3
)
When you set the position switch
○
h at "0" and
press the set button
○
g for 3 sec., a "0" will be
displayed with a dot in the corner of the
7-segment LED
○
f , and alarm LED
○
b
flashes.
Mode
switch
○
e
Position
switch
○
h
Alarm
LED
○
b
7-segment
LED
○
f
Reverse
button
○
j
Forward
button
○
i
Power
supply
LED
○
a