- 5 -
1. Start up procedures / Simple settings for quick start
The procedures from purchasing to start up using a PLC are explained below.
1. 1 Preparation
(1) Items to be prepared
Please check the part numbers on the product labels and the quantity of the accessories to confirm
that the order is correct.
LAT3 series
Part No.
Description
Quantity
LAT3
∗
-
∗
Card Motor
1 pc
LATH1-
∗
Actuator cable
1 pc
LATC4-
∗
Card Motor controller
1 pc
(Accessory)
Power supply plug
1 pc
(Accessory)
Counter plug
1 pc
LATC-W1
Controller setting kit
1 pc
(Accessory)
Controller setting cable
1 pc
Items to be prepared by the user
.
Description
Conditions
Controller power
supply DC24V
Power supply voltage: 24 VDC
+/-
10%, 3A or more
(Do not use inrush current limiting type)
Power supply cable
20 AWG / 0.5 mm
2
Use a single multi-strand wire for each terminal.
Twist the wires together, and strip the ends as
shown.
∗
The insulation should be rated to withstand
60
o
C temperature minimum.
Wiring of the
power supply plug
Connect the positive terminal of the 24 VDC power supply to the
DC1(+) terminal of the controller power supply plug,
and the negative terminal to the DC1(-) terminal.
Grounding cable
Cable with crimped terminal (cross sectional area: greater than 2 mm
2
)
Connect to the controller backplate using an M4 screw and
a shakeproof washer.
PC
PC with WindowsXP or Windows7 and USB1.1 or USB2.0 port.
∗
Windows
, WindowsXP , and Windows7 are registered trademarks of the United
States Microsoft Corporation.
Open / close lever
Push the open / close lever and insert
the wire into the electrical wire entry.
Electrical wire entry
DC1(+)
Controller
power supply plug
24V
Power supply
(24 VDC)
0V
DC1(-)
Card Motor
Actuator cable
Controller setting cable
Counter plug
Controller
Controller setting kit
Power supply plug
8mm
Stripped wire length