(4) Continuous Operation
The operation of a continuous cycle can be checked in accordance with the procedure below.
A. Selection of Return to Origin Position
・・・・・
Select Step “1”, and select the "Return to Origin" option in the ”Step Data Number” column, and tick
the "One Time Ope” operation check box.
B. Selection of Step Data
・・・・・
Select and enter the step data in the order they are to be executed from Step 2 onwards (Step 20 is
maximum possible) and enter the required [Operatiing Time] for each step.
Note)
C. Setting the [Repeat Count]
・・・・・
Enter the amount of times the cycle is to be repeated.
D. Press [Operation Start] to start the operation.
E. Operation End
・・・・・
The operation ends and the motor becomes de-energized after the Card Motor has repeated the
amount of cycles set in the [Repeat Count] text box in item C in the figure below.
If it is necessary to stop the operation while the product is operating, click [Operation End] (item E
shown below) and the motor becomes de-energized.
Note) Operating Time: Time required from the start of one step data operation to the start of the next
step data operation. Enter a value larger than the ”Positioning Time” of the
selected step data.
It is not necessary to enter "Operating Time" for the “Return to Origin Position”
function.
The Card Motor will execute the steps in the order they are entered in item B
shown below after the ”Return to Origin Position” operation has been
completed.
A
B
C
D E