manualshive.com logo in svg
background image

A, B port size: 

Ø 

2, 

Ø 

4, 

Ø 

6

A, B port size: 

Ø 

6, 

Ø 

8

A, B port size: 

Ø 

10, 

Ø 

12

6.4 

mm

10 

mm

15 

mm

Ø 25

Ø 40

Ø 63

100

300

500

310

550

140

Ø 40

Ø 50

Ø 100

100

300

500

430

520

110

100

300

500

Ø 63

Ø 80

Ø 160

540

360

100

New

New

New

Bore size [mm]

Bore size [mm]

Bore size [mm]

Cylinder speed [mm/s]

Cylinder speed [mm/s]

Cylinder speed [mm/s]

Ø 6 One-touch fitting

Ø 8 One-touch fitting

Ø 12 One-touch fitting

Refer to pages 9 to 12 for detailed conditions regarding the above cylinder speeds.

Size reduction has been made possible thanks to a flow increase.

This allows for 

space saving

weight reduction

, and a 

large flow rate

.

Can drive 

Ø 

40

1

 bore cylinders

Can drive 

Ø 

50

1

 bore cylinders

Can drive 

Ø 

80

1

 bore cylinders

JSY1000

JSY3000

JSY5000

JSY1000

JSY3000

JSY5000

1  The cylinder speed is 300 mm/s.

Can be connected with the ZK2 series 
vacuum unit

p. 

7

JSY3000

Vacuum Unit 

ZK2

Ejector System

JSY1000/3000/5000

 Series

CAT.EUS11-110B-UK

Compact 5-Port Solenoid Valve

Plug-in

Содержание JSY1000 Series

Страница 1: ...r to pages 9 to 12 for detailed conditions regarding the above cylinder speeds Size reduction has been made possible thanks to a flow increase This allows for space saving weight reduction and a large...

Страница 2: ...tion 39 reduction 36 reduction 35 reduction Wiring Plug in Compact 5 Port Solenoid Valve JSY1000 3000 5000 Series 1597 691 263 10 6 4 15 5 24 6 JSY1000 JSY3000 JSY5000 Q l min ANR 760 a 1597 Q l min A...

Страница 3: ...valves built into one body Plug in Compact 5 Port Solenoid Valve JSY1000 3000 5000 Series Plug in Series A side B side JSY A0 N C valve N C valve JSY B0 N O valve N O valve JSY C0 N C valve N O valve...

Страница 4: ...om both the pneumatic circuit and the electric side Devices including valves need to be selected based on whether their functions are in line with the safety level of the equipment as a whole The use...

Страница 5: ...5 5 5 Application Examples Plug in Compact 5 Port Solenoid Valve JSY1000 3000 5000 Series JSY5000 JSY3000 JSY1000 5...

Страница 6: ...ly p 132 p 132 p 132 Flow rate Q l min ANR 4 2J5 3 A BJEA EB Type of actuation Rated voltage Port size 4 A 2 B port 1 P 3 5 E port 2 4 6 8 10 12 4 A 2 B port JSY1000 4 250 24 VDC 8 6 263 JSY3000 8 691...

Страница 7: ...ing disk label SUP blocking disk label A 4 B 2 A 4 B 2 A 4 B 2 A 4 B 2 A 4 B 2 D D D 3 5 E 1 P 3 5 E P 1 2 B p 130 p 133 7 Pitch width mm Wiring Manifold options Valve options Commonspecifications Bla...

Страница 8: ...ions 1 to 8 stations Max number of outputs 16 The centralised electrical wiring can be connected to the fieldbus system Integrated manifold Centralised wiring and piping directions Specifications Vari...

Страница 9: ...uilt in Silencer Mixed Size Straight Port Type p 97 Manifold Exploded View By Wiring p 101 D sub Connector Flat Ribbon Cable IP40 Connector Entry Direction Adjustable p 102 D sub Connector IP67 p 103...

Страница 10: ...nder Values at extension of a directly coupled cylinder when meter out speed controllers are used with the needle full open The average speed of the cylinder is obtained by dividing the stroke by the...

Страница 11: ...ical Upward Optimum Actuation Size Chart of Air Cylinder Values at extension of a directly coupled cylinder when meter out speed controllers are used with the needle full open The average speed of the...

Страница 12: ...al Upward Optimum Actuation Size Chart of Air Cylinder Values at extension of a directly coupled cylinder when meter out speed controllers are used with the needle full open The average speed of the c...

Страница 13: ...um Actuation Size Chart of Air Cylinder Values at extension of a directly coupled cylinder when meter out speed controllers are used with the needle full open The average speed of the cylinder is obta...

Страница 14: ...o 0 7 3 position 0 2 to 0 7 4 position dual 3 port valve 0 15 to 0 7 External pilot Made to Order operating pressure range MPa Operating pressure range 100 kPa to 0 7 Pilot pressure range 2 position s...

Страница 15: ...5 25 JSY5200 2 position double 19 17 JSY53 4 500 3 position 41 37 JSY5A B C00 4 position dual 3 port valve 37 37 JSY1000 Series Valve Weight JSY3000 Series Valve model Type of actuation Weight g JSY3...

Страница 16: ...EA 5 1 P 3 EB A 4 2 B 3 position pressure centre EA 5 1 P 3 EB A 4 2 B 3 position exhaust centre EA 5 1 P 3 EB A 4 2 B 4 position dual 3 port valve N C valve x 2 pcs 5 EA 3 EB 1 P 4 A 2 B N O valve x...

Страница 17: ...types of lengths for the pilot valve mounting screws 3 The pilot valve of the JSY1000 cannot be removed This is irreplaceable How to replace pilot valves 1 The coil specification and voltage includin...

Страница 18: ...5000 1 The FW type is not available for the JSY1000 Protection class for the JSY1000 is IP20 or IP40 2 The FC PC PGC and PHC types are not available for the JSY5000 Model q Per station w Wiring D sub...

Страница 19: ...only The valve weight is not included To obtain the weight with valves attached add the valve weight given on page 14 for the appropriate number of stations 2 The FW type is not available for the JSY1...

Страница 20: ...OL a SOL b Station 1 Station 2 Station 3 20 Connector Wiring Layout For both serial and parallel wiring additional valves are sequentially assigned pins on the connector This makes it completely unnec...

Страница 21: ...21 21...

Страница 22: ...desired order with a specified layout 2 Specified layout Indicate the wiring specifications on the manifold specification sheet Note that 2 position double 3 position and 4 position valves cannot be u...

Страница 23: ...le for the JSY1000 series When the non polar common specification type is selected take measures to prevent surge voltage For details refer to page 138 yManual override Push turn locking lever type E...

Страница 24: ...age 100 for dimensions Type 10 SidePorted Applicable to 2 and 4 fittings D sub Connector IP40 Connector Entry Direction Adjustable JSY1000 3000 5000 Series 43 2 2 x M2 6 66 5 70 6 5 3 7 9 8 L5 L1 12 2...

Страница 25: ...S Single wiring D side U side For DIN rail mounting 25 JJ5SY1 10F C6 D 1 2 U D B Dimensions JSY1000 Series Stations n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 101 110 119 128...

Страница 26: ...ck internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 26 Dimensions JSY3000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 93...

Страница 27: ...d block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 27 JJ5SY5 10F1 2 D U D B C10 C12 Dimensions JSY5000 Series Stations n Stations L Dimensions n L...

Страница 28: ...ternal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 28 JJ5SY3 10FW D 1 2 U D B C6 C8 Dimensions JSY3000 Series Stations n Stations L Dimensions n L 2 3 4 5 6...

Страница 29: ...ock internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 29 Plug in Connector Connecting Base JSY1000 3000 5000 Series JJ5SY5 10FW D 1 2 U D B C10 C12 Dimen...

Страница 30: ...de For DIN rail mounting 30 JJ5SY1 10FC D 1 2 U D B C2 C4 Dimensions JSY1000 Series Stations n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 77 1 83 6 90 1 96 6 103 1 109 6 116 1 1...

Страница 31: ...Flat Ribbon Terminal Block Connector Connecting Base Plug in Common Dimensions Made to Order Manifold Exploded View ZK2 Combination Manifold Manifold Options Specific Product Precautions Fittings Rep...

Страница 32: ...l wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 32 JJ5SY3 10FC D 1 2 U D B C6 C8 Dimensions JSY3000 Series Stations n Stations L Dimensions n L 2 3 4 5 6 7 8...

Страница 33: ...cifications Double wiring S Single wiring D side U side For DIN rail mounting 33 Plug in Connector Connecting Base JSY1000 3000 5000 Series JJ5SY1 10 D 1 2 U D B P PG PH C2 C4 Dimensions JSY1000 Serie...

Страница 34: ...tubing O D 8 SMC Manifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 34 Dimensions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8...

Страница 35: ...Applicable tubing O D 10 SMC Manifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 35 Dimensions JSY3000 Series n Stations L Dimensions n L 2...

Страница 36: ...Yellow One touch fitting 1 P 3 5 E port Applicable tubing O D 12 SMC Manifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 36 Dimensions JSY50...

Страница 37: ...connector 20 pins Conforming to MIL C 83503 37 Dimensions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 72 1 78 6 85 1 91 6 98 1 104 6 111 1 117 6 124 1 130 6 137...

Страница 38: ...tions Double wiring S Single wiring D side U side For DIN rail mounting 38 Dimensions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 77 1 86 1 95 1 104 1 113 1 122...

Страница 39: ...ifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 39 Dimensions JSY3000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15...

Страница 40: ...ition 25 pins GVVZS3000 21A 60 angled Standard When using a valve with no polarity either positive common or negative common can be used Wire colour table by terminal number of D sub connector cable a...

Страница 41: ...9 18 17 26 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 COM COM Positive common Negative common Station 1 Terminal no Polarity SOL a SOL a SOL a SOL a SOL a SOL a SOL a SOL a SOL a SOL a SOL a SOL a SOL b S...

Страница 42: ...3M Japan Limited Fujitsu Limited Japan Aviation Electronics Industry Limited J S T Mfg Co Ltd Oki Electric Cable Co Ltd When using a standard commercial connector use a 26 pin 20 pin or 10 pin type co...

Страница 43: ...43 43...

Страница 44: ...specified layout 2 Specified layout Indicate the wiring specifications on the manifold specification sheet Note that 2 position double 3 position and 4 position valves cannot be used where single wiri...

Страница 45: ...5 station manifold base part no JSY3100 5U 2 sets 2 position single part no JSY3200 5U 3 sets 2 position double part no The asterisk denotes the symbol for the assembly Prefix it to the part numbers o...

Страница 46: ...ting 46 Dimensions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 138 5 145 151 5 158 164 5 171 177 5 184 190 5 197 203 5 210 216 5 223 229 5 L2 56 4 62 9 69 4 75 9...

Страница 47: ...ns JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 143 5 152 5 161 5 170 5 179 5 188 5 197 5 206 5 215 5 224 5 233 5 242 5 251 5 260 5 269 5 L2 61 4 70 4 79 4 88 4 9...

Страница 48: ...iring S Single wiring D side U side For DIN rail mounting 48 Dimensions JSY3000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 146 1 157 6 169 1 180 6 192 1 203 6 215 1 226...

Страница 49: ...wiring D side U side For DIN rail mounting 49 Dimensions JSY5000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 165 5 181 5 197 5 213 5 229 5 245 5 261 5 277 5 293 5 309 5...

Страница 50: ...D 8 SMC Manifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 50 Dimensions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11...

Страница 51: ...8 SMC Manifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 51 Dimensions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12...

Страница 52: ...Yellow One touch fitting 1 P 3 5 E port Applicable tubing O D 10 SMC Manifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 52 Dimensions JSY3...

Страница 53: ...g 1 P 3 5 E port Applicable tubing O D 12 SMC Manifold block internal wiring specifications Double wiring S Single wiring D side U side For DIN rail mounting 53 Dimensions JSY5000 Series n Stations L...

Страница 54: ...ow only after confirming that the gasket is installed correctly Step 1 Remove the terminal block cover Loosen the 4 mounting screws M3 to remove the terminal block cover Step 2 The diagram below shows...

Страница 55: ...side according to the markings provided inside the terminal block Specified Layout A mixture of single and double wiring can be specified on the manifold specification sheet The maximum number of sta...

Страница 56: ...B port JSY1000 JSY3000 JSY5000 C2 Straight 2 C4 4 C6 6 C8 8 C10 10 C12 12 CM 1 Straight port mixed sizes P E port size One touch fittings 8 10 12 1 Indicate the sizes on the manifold specification sh...

Страница 57: ...JSY1000 series When the non polar common specification type is selected take measures to prevent surge voltage For details refer to page 138 y Manual override Push turn locking lever type E is not av...

Страница 58: ...unting 58 Dimensions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 107 5 114 120 5 127 133 5 140 146 5 153 159 5 166 172 5 179 185 5 192 198 5 L2 56 4 62 9 69 4 75...

Страница 59: ...ions JSY1000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 112 5 121 5 130 5 139 5 148 5 157 5 166 5 175 5 184 5 193 5 202 5 211 5 220 5 229 5 238 5 L2 61 4 70 4 79 4 88 4...

Страница 60: ...iring S Single wiring D side U side For DIN rail mounting 60 Dimensions JSY3000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 115 1 126 6 138 1 149 6 161 1 172 6 184 1 195...

Страница 61: ...wiring D side U side For DIN rail mounting 61 Dimensions JSY5000 Series n Stations L Dimensions n L 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 L1 134 5 150 5 166 5 182 5 198 5 214 5 230 5 246 5 262 5 278 5...

Страница 62: ...n resistance M km 20 C 10 or more JSY1000 3000 5000 Series Lead wire AWG26 0 14 mm2 x 34 cores Sheath O D Approx 8 8 34 cores 11 12 13 14 15 23 24 25 26 17 18 19 20 21 1 22 16 27 10 9 8 6 5 7 4 3 2 34...

Страница 63: ...h sides Type Colour Orange Red Black Light grey Red Black White Red Black Yellow Red Black Pink Red Black Orange Red Black Light grey Red Black White Red Black Yellow Red Lead wire colour Printed mark...

Страница 64: ...is different depending on the selected fitting o Mounting and Option Symbol Mounting Direct mounting D DIN rail mounting Enter the number of stations inside when it is larger than the number of valve...

Страница 65: ...utput polarity is positive common Select U or NZ for the valve when the SI unit output polarity is negative common Only Z and NZ types are available for the JSY1000 series When the non polar common sp...

Страница 66: ...635 5 635 5 648 648 8 560 5 560 5 573 573 585 5 585 5 598 598 610 5 610 5 623 623 635 5 648 648 660 5 660 5 673 673 685 5 685 5 698 698 9 610 5 610 5 623 623 635 5 635 5 648 648 660 5 660 5 673 673 6...

Страница 67: ...73 673 685 5 698 710 5 710 5 8 560 5 573 585 5 585 5 598 610 5 610 5 623 635 5 648 648 660 5 673 685 5 685 5 698 710 5 710 5 723 735 5 748 748 760 5 9 610 5 623 623 635 5 648 660 5 660 5 673 685 5 685...

Страница 68: ...648 660 5 660 5 673 8 573 585 5 585 5 598 598 610 5 610 5 623 623 635 5 635 5 648 648 660 5 660 5 673 673 685 5 685 5 698 698 710 5 723 9 623 623 635 5 635 5 648 648 660 5 660 5 673 685 5 685 5 698 69...

Страница 69: ...585 5 598 598 610 5 623 635 5 635 5 648 660 5 673 673 685 5 698 698 710 5 723 735 5 8 573 585 5 598 610 5 610 5 623 635 5 648 648 660 5 673 673 685 5 698 710 5 710 5 723 735 5 735 5 748 760 5 773 773...

Страница 70: ...ions These figures show the JJ5SY3 10S6Q22 05D C8 Refer to page 98 for dimensions of external pilot Made to Order and silencer L1 11 5 x n1 136 6 47 x n2 L2 11 5 x n1 43 1 L4 L3 10 5 L5 L3 L1 2 L6 47...

Страница 71: ...C6 C8 Stations These figures show the JJ5SY3 10S6Q32 05D C8 Refer to page 98 for dimensions of external pilot Made to Order and silencer L1 11 5 x n1 153 1 47 x n2 L2 11 5 x n1 43 1 L4 L3 10 5 L5 L3 L...

Страница 72: ...0S6 D U D B C10 C12 Stations These figures show the JJ5SY5 10S6Q22 05D C12 Refer to page 99 for dimensions of external pilot Made to Order and silencer L1 16 x n1 147 47 x n2 L2 16 x n1 53 5 L4 L3 10...

Страница 73: ...5D C12 Refer to page 99 for dimensions of external pilot Made to Order and silencer L1 16 x n1 163 5 47 x n2 L2 16 x n1 53 5 L4 L3 10 5 L5 L3 L1 2 L6 47 x n2 81 5 n1 Valve stations n2 I O unit station...

Страница 74: ...osition valves cannot be used where single wiring has been specified This also includes the number of the blanking plate assembly r With or without I O modules Without I O module Y With I O module Whe...

Страница 75: ...O r Rated voltage 5 24 VDC t Light surge voltage suppressor and common specification Symbol With light Surge voltage suppressor Common specification U Non polar NZ Negative common When the non polar...

Страница 76: ...0 L1 L3 L2 85 54 54 83 120 14 5 97 9 83 65 5 61 5 66 23 9 18 3 15 8 14 8 13 6 10 9 5 5 27 7 17 5 7 5 1 5 9 9 2 4 6 C8 14 9 P 11 5 17 4 5 X2 4 X0 0 1 7 6 X3 3 X1 2 13 X6 12 9 X4 8 5 X2 4 1 X0 0 15 14 X...

Страница 77: ...00 Series JJ5SY5 10SACN 90 L1 L3 L2 85 54 54 83 120 14 5 128 8 97 5 26 3 96 6 61 5 73 2 29 1 11 1 8 7 P 16 22 7 18 5 5 17 5 7 5 1 8 5 5 15 8 C12 16 7 23 3 27 7 13 X6 12 9 X4 8 5 X2 4 1 X0 0 5 X2 4 X0...

Страница 78: ...es the number of blanking plates For the product without the SI unit S0 note the maximum number of solenoids of the SI unit that will be mounted If the layout is specified indicate it on the manifold...

Страница 79: ...not CC Link applicable Only Z and NZ types are available for the JSY1000 series When the non polar common specification type is selected take measures to prevent surge voltage For details refer to pa...

Страница 80: ...igures show the JJ5SY1 10SQ1A 05D C4 Refer to page 97 for dimensions of external pilot Made to Order and silencer When CM is selected for mixed A B port size and C6 9 mm pitch is included refer to pag...

Страница 81: ...the JJ5SY1 10SQ1A 05D C6 Refer to page 97 for dimensions of external pilot Made to Order and silencer When CM is selected for mixed A B port size refer to page 100 for dimensions L1 9 x n1 139 21 x n...

Страница 82: ...5 548 560 5 573 585 5 598 610 5 JJ5SY3 10S D U D B C6 C8 Stations These figures show the JJ5SY3 10SQ1A 05D C8 Refer to page 98 for dimensions of external pilot Made to Order and silencer L1 11 5 x n1...

Страница 83: ...5 10S D U D B C10 C12 Stations These figures show the JJ5SY5 10SQ1A 05D C12 Refer to page 99 for dimensions of external pilot Made to Order and silencer L1 16 x n1 147 21 x n2 L2 16 x n1 53 5 L4 L3 10...

Страница 84: ...rt size Metric One touch fitting Symbol A B port JSY1000 JSY3000 JSY5000 C2 Straight 2 C4 4 C6 6 C8 8 C10 10 C12 12 CM 1 Straight port mixed sizes P E port size One touch fittings 8 10 12 1 Indicate t...

Страница 85: ...output polarity is N negative common Only Z and NZ types are available for the JSY1000 series When the non polar common specification type is selected take measures to prevent surge voltage For detai...

Страница 86: ...ailable for the product without the SI unit S0 DIN Rail Option DIN rail mounting With DIN rail 0 DIN rail mounting Without DIN rail 3 For 3 stations Specify a length longer than that of the standard r...

Страница 87: ...selected take measures to prevent surge voltage For details refer to page 138 When ordering a valve individually the base gasket is not included Since the base gasket is attached to the manifold pleas...

Страница 88: ...B port size and C6 9 mm pitch is included refer to page 100 for dimensions Type 10 SidePorted Applicable to 2 and 4 fittings EX260 JSY1000 3000 5000 Series L3 L2 5 3 1 5 66 5 78 6 23 8 5 3 L1 L5 12 2...

Страница 89: ...mixed A B port size refer to page 100 for dimensions Type 10 Side Ported Applicable to 6 fittings EX260 Plug in Connector Connecting Base JSY1000 3000 5000 Series L4 P 9 66 5 78 6 23 8 5 3 L1 L5 12 9...

Страница 90: ...ternal pilot Made to Order and silencer Type 10 Side Ported EX260 JSY1000 3000 5000 Series L4 P 11 5 85 5 83 114 8 16 9 9 9 L1 L5 8 97 9 65 5 46 2 2 35 4 6 5 5 14 9 14 8 L3 L2 34 7 5 3 1 5 17 1 38 1 7...

Страница 91: ...ade to Order and silencer Type 10 Side Ported EX260 Plug in Connector Connecting Base JSY1000 3000 5000 Series L4 P 16 102 4 97 5 26 3 14 L1 L5 L3 L2 34 2 5 3 1 5 16 7 15 8 8 128 8 96 6 77 1 1 8 35 5...

Страница 92: ...ot Built in silencer The 3 5 E port is plugged for the built in silencer type The external pilot specification should be ordered as Made to Order For details refer to page 135 For details on the EX120...

Страница 93: ...specification is ZBN negative common Only Z and NZ types are available for the JSY1000 series When the non polar common specification type is selected take measures to prevent surge voltage For detail...

Страница 94: ...SidePorted Applicable to 2 and 4 fittings EX120 JSY1000 3000 5000 Series L4 P 6 5 6 2 L1 12 2 14 8 8 L3 L2 5 3 1 5 8 9 23 9 10 2 21 59 9 27 7 5 13 6 10 3 78 5 2 2 66 5 47 3 5 3 26 1 9 5 35 4 6 5 5 64...

Страница 95: ...6 fittings EX120 Plug in Connector Connecting Base JSY1000 3000 5000 Series L4 P 9 6 2 L1 12 9 14 8 L3 L2 5 3 1 5 8 9 23 9 11 5 59 9 25 8 7 5 13 6 9 1 21 64 14 5 41 6 56 3 61 78 5 66 5 47 3 9 5 2 2 5...

Страница 96: ...Series L4 P 11 5 2 6 2 64 83 21 4 9 9 L1 L5 14 9 14 8 8 97 9 65 5 46 2 35 4 6 5 5 L3 L2 39 8 5 3 1 5 17 1 38 1 61 51 5 15 8 17 4 66 23 9 7 5 13 6 10 9 11 8 A B A 4 B 2 A B A 4 B 2 A B A 4 B 2 A B A 4...

Страница 97: ...se JSY1000 3000 5000 Series L4 P 16 6 2 64 97 5 26 3 52 3 L1 L5 L3 L2 39 3 5 3 1 5 16 7 15 8 8 128 8 96 6 77 1 1 8 35 5 5 5 5 12 5 30 5 61 18 23 3 73 2 29 1 10 11 1 8 7 56 14 3 A B B 2 4 A A B B 2 4 A...

Страница 98: ...B 4 A B 2 A B 4 A B 2 A B 4 A B 2 PE 1P 3 5E 3 5 1 P E S D D 4 A B 2 4 A B 2 4 A B 2 4 A B 2 E 3 5 P 1 4 A B 2 A B 4 A B 2 A B A 2 Built in silencer Internal pilot P E port entry D These figures show...

Страница 99: ...4 B 2 A B A 4 B 2 A B A 4 B 2 X 3 5E 1P PE A 4 B 2 A 4 B 2 A 4 B 2 A 4 B 2 A 4 B 2 S D D 3 5 E 1 P 3 5 E P 1 A B A 4 B 2 A B A 4 2 These figures show the JJ5SY3 10F2 05DR C8 Calculation formula for L...

Страница 100: ...A B B 2 4 A A B B 2 4 A 3 5E PE 1P S 1 P E 3 5 3 5 E P 1 2 B A 4 2 B A 4 2 B A 4 2 B A 4 2 B A 4 D D A B B 2 4 A A B 2 4 A Fitting for the type with P E ports on the U and or D sides D side U side Sta...

Страница 101: ...itch manifold block stations Applicable fittings 6 n3 Number of I O units or input block stations FW D sub connector IP67 is not available for the JSY1000 Type 10 Side Ported Mixed Size Straight Port...

Страница 102: ...e 10 D sub Connector Flat Ribbon Cable IP40 Connector Entry Direction Adjustable p 102 D sub Connector IP67 For JSY3000 5000 p 103 D sub Connector Flat Ribbon Cable IP20 Compact Type For JSY1000 3000...

Страница 103: ...15 1A The part number is for 1 piece C10 Mounting Direct mounting D0 DIN rail mounting Without DIN rail P E port size One touch fittings Symbol P E port JSY1000 JSY3000 JSY5000 C8 8 One touch fitting...

Страница 104: ...R type SUP EXH block assembly D side accessories and the number of accessories Accessories JSY3000 JSY5000 a Tension bolt None 1 3 pcs 1 Since the nuts are embedded in the SUP EXH block eClamp bracket...

Страница 105: ...port size One touch fittings Symbol P E port JSY1000 JSY3000 C8 8 One touch fitting C10 10 One touch fitting 00 1 Plug 1 Can be selected when the pilot silencer type symbol is or S Not available for R...

Страница 106: ...uch fitting C10 10 One touch fitting C12 12 One touch fitting 00 1 Plug 1 Can be selected when the pilot silencer type symbol is or S Not available for R type SUP EXH block assembly D side accessories...

Страница 107: ...ype symbol is or S Not available for R type SUP EXH block assembly D side accessories and the number of accessories Accessories JSY1000 JSY3000 JSY5000 a Tension bolt None 1 3 pcs 1 Since the nuts are...

Страница 108: ...1 Plug 1 Can be selected when the pilot silencer type symbol is or S Not available for R type SUP EXH block assembly D side accessories and the number of accessories Accessories JSY1000 JSY3000 JSY500...

Страница 109: ...C10 10 One touch fitting C12 12 One touch fitting 00 1 Plug Wireless compatible Output type Symbol Description 1 PNP Negative common 2 NPN Positive common Protocol Symbol SI unit type Description EN...

Страница 110: ...s and connector tEX600 analogue input output unit EX600 AX A Analogue input output Symbol Description AX Analogue input AY Analogue output Symbol Number of input channels Connector A 2 channels M12 co...

Страница 111: ...ilot Silencer type Symbol Pilot type Built in silencer Internal External Made to Order S R The 3 5 E port is plugged for the built in silencer type P E port size One touch fittings Symbol P E port JSY...

Страница 112: ...or manifold valve part numbers Bracket 3 to 5 correspond to the mounting hole pitch of each manifold valve EX245 DX1 Digital input module specification DX1 Digital input 16 inputs EX245 DY1 Digital ou...

Страница 113: ...o Order S R The 3 5 E port is plugged for the built in silencer type eClamp bracket Series Part no JSY1000 JSY11M 15P 2A JSY3000 SY30M 15 1A JSY5000 SY50M 15 1A The part number is for 1 piece Series 1...

Страница 114: ...common M12 KAN MJ4 Sink NPN Positive common VB 1 Enclosure is IP40 when the communication connector is D sub EX260 Refer to pages 115 to 117 for details on common parts JSY 3 C10 1M 1P 1A Pilot Silen...

Страница 115: ...ittings Symbol P E port JSY1000 JSY3000 JSY5000 C8 8 One touch fitting C10 10 One touch fitting C12 12 One touch fitting 00 1 Plug SUP EXH block assembly D side accessories and the number of accessori...

Страница 116: ...k assembly Refer to page 116 for ordering single unit w Connector gasket is not applicable to the JSY1000 No Description Quantity Note qwe Gasket 1 pc of each For base connector and manifold block r T...

Страница 117: ...0 JJ5SY5 10 cannot be assembled by connecting the tie rods for additional stations for the number of manifold Tie rod SV2000 55 1 A is necessary 2 Part number of the clamp bracket for the JSY1000 is d...

Страница 118: ...0 S type iClamp bracket Series Part no JSY1000 For D0 JSY11M 15P 1A For D00 JSY11M 15P 2A JSY3000 SY30M 15 1A JSY5000 SY50M 15 1A The part number is for 1 piece Part number of the JSY1000 is different...

Страница 119: ...119...

Страница 120: ...wn in the table above for details RoHS yValve stations 1 Double wiring 2 position single double 3 position and 4 position valves can be used on all manifold stations The use of a 2 position single sol...

Страница 121: ...ordering Refer to the bottom of this page for an order example qSeries 3 JSY3000 ePilot valve exhaust method 0 Pilot valve individual exhaust wType of actuation 1 2 position Single 2 Double 3 3 positi...

Страница 122: ...ow adjusting needle Screwdriver operation type long lock nut Used when the port position is close to the manifold s individual supply and needle adjustment is difficult J Round lock nut Thicker than t...

Страница 123: ...Release valve Symbol Voltage 5 24 VDC q Body Exhaust type Symbol Body Exhaust type C For Manifold Complex exhaust 1 F Individual port exhaust H High noise reduction silencer exhaust 1 Combination of...

Страница 124: ...n ejectors refer to the ZK2 A series in the Web Catalogue Refer to page 125 for dimensions of external pilot and built in silencer Refer to pages 69 70 and 81 for dimensions when L6 and b are used for...

Страница 125: ...ire length 10 1 10 3 Pressure sensor 15 4 38 7 3000 Lead wire length 8 7 One touch fitting Option 1 Common supply PS port Applicable tubing O D 6 SMC One touch fitting Option 2 Common supply PD port A...

Страница 126: ...82 5 One touch fitting PE Pilot EXH port X External pilot port Applicable tubing O D 4 SMC For P E ports on the U side or both sides PS 2B 4 A B A 2B 4 A B A 2B 4 A B A 2B 4 A B A Silencer Exhaust po...

Страница 127: ...y is installed select a tie rod that is 2 stations longer D End block assembly Includes a and b C a 1 o 3 o 2 End plate U 1DIN rail mounting spacer Mounted only on models with a DIN rail mounting brac...

Страница 128: ...unting Without DIN rail P E port size One touch fitting Symbol P E port JSY3000 C10 10 One touch fitting 125P Tension bolt Short Tightening torque 0 8 N m a 1 Tension bolt Long Tightening torque 0 8 N...

Страница 129: ...Tightening torque 0 15 N m 11 For products with a switch mount the switch assembly Be careful not to drop the O ring Tightening torque 0 08 to 0 10 N m To increase the number of stations from an even...

Страница 130: ...15 16 34 35 41 Station 1 Station 2 Station 3 Station 4 Station 5 Station 6 Station 7 Station 8 Terminal no Supply valve Release valve Supply valve Release valve Supply valve Release valve Supply valve...

Страница 131: ...39 for assembling when a fitting is replaced Series Piping port JSY1000 JSY3000 JSY5000 Note For A B port C2 C4 fittings For A B port C6 fittings A B port Clip SJ1000 CL 1 JSY11M 19P 1A JSY31M 19P 1A...

Страница 132: ...249 3 No 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 L dimension 573 585 5 598 610 5 623 635 5 648 660 5 673 685 5 698 710 5 723 735 5 748 760 5 773 785 5 798 Weight g 145 148 1 151 3 154...

Страница 133: ...P The body and plug in spacer of the JSY1000 are separate The connector gasket is not used The body and plug in spacer of the JSY1000 are separate The connector gasket is not used Port size One touch...

Страница 134: ...osition where the blocking disk is inserted will be labeled and shipped out Shipped together with the product Labels for blocking disks These labels can be used to indicate and confirm where on the ma...

Страница 135: ...B B 2 4 A 1P A B 4 A B 2 2 B A 4 A B B 2 4 A 3 5 E P 1 2 B A 4 D 4 A B 2 E 3 5 P 1 4 A B 2 D A B 4 A B 2 P A B A 4 B 2 D A 4 B 2 A 4 B 2 D 3 5 E P 1 A B A 4 B 2 P 1 73 2 128 8 97 9 66 78 5 59 9 88 7 3...

Страница 136: ...JJ5SY 1 3 5 1 3 5 S S3 T TC S6 S 10 10 R R The combination of external pilot type R and silencer type S is not available Only the JSY3000 5000 can be selected for the EX245 G P E port entry External p...

Страница 137: ...osive gases chemicals sea water water water vapour or where there is direct contact with any of these 2 Products compliant with IP67 enclosures based on IEC 60529 are protected against dust and water...

Страница 138: ...rgise the A side and B side of 2 position double solenoid valve at the same time Positive common Single solenoid Negative common Single solenoid Positive common Double solenoid 3 position 4 position N...

Страница 139: ...tion and the valve in a de energised state may switch over see Figure 1 When installing a breaker circuit for the loading power supply consider using a valve with polarity with polarity protection dio...

Страница 140: ...here will be an unused control signal To avoid this indicate positions of manifold blocks for single wiring specification and double wiring specification on a manifold specification sheet Note that do...

Страница 141: ...led securely all the way into the fitting this can cause problems such as air leakage or the tube pulling out 2 Tube detachment Use the release tool when the removal of tube is difficult due to the tu...

Страница 142: ...Connector Connecting Base Flat Ribbon Cable Compact Type 26 pins IP20 p 21 JJ5SY3 10PG JSY3000 Type 10 Side Ported Plug in Connector Connecting Base Flat Ribbon Cable Connector Entry Direction Adjusta...

Страница 143: ...of SMC products with production equipment for the manufacture of weapons of mass destruction WMD or any other weapon is strictly prohibited 2 The exports of SMC products or technology from one country...

Страница 144: ...e fr Germany 49 0 61034020 www smc de info smc de Greece 30 210 2717265 www smchellas gr sales smchellas gr Hungary 36 23513000 www smc hu office smc hu Ireland 353 0 14039000 www smcautomation ie sal...