6
3. Product Specifications
3-1. Specifications
Specifications
*The sensing position of the auto switch is fixed to the open end and closed end of the finger.
* When detecting the gripping position of the workpiece, secure the auto switch at the appropriate
position according to the shape of the workpiece.
* For examples of setting auto switch and setting of mounting position of auto switches, please refer to
the JMHZ2 Series catalogue P.15 onwards on our website (www.smcworld.com).
Model
JMHZ2-16D-X7400B-TM
Bore size (mm)
16
Fluid
Air
Operating pressure [MPa]
0.1 to 0.7
Ambient and fluid temperature (
o
C)
-10 to 50
Repeatability (mm)
±0.01
Maximum operating frequency (c.p.m.)
120
Lubrication
Non-lube
Action
Double acting
Gripping force
Actual value per finger (N)
External gripping
Force (N)
32.7
Internal gripping
Force (N)
43.5
Opening/closing stroke (both) (mm)
10
Weight (g)
430
Auto switch model
D-M9N-5
Standard for mounting interface
ISO9409-1-50-4-M6
Connector configuration
M8 8Pin(Plug)
Detecting position of the
open end of the finger
Detecting position of the
closed end of the finger