  Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”

 

They are all important notes for safety and must be followed in addition to International Standards (ISO/IEC)

*1)

 , 

and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines.(Part 1: General requirements)

 

   

ISO 10218: Manipulating industrial robots -Safety.

                                                                                 

 

 

  etc.

 

     

 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result 

in minor or moderate injury.

 

 
 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications.

 

Since  the  product  specified  here  is  used  under  various  operating  conditions,  its  compatibility  with  specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This  person  should  also  continuously  review  all  specifications  of  the  product  referring  to  its  latest  catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The  assembly,  operation  and  maintenance  of  machines  or  equipment  including  our  products  must  be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

 

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented 
    and the power from any appropriate source is cut, and read and understand the specific product precautions 
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
    direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

4.Use  in  an  interlock  circuit,  which  requires  the  provision  of  double  interlock  for  possible  failure  by  using  a 

mechanical protective function, and periodical checks to confirm proper operation. 

 

 

Содержание IZG10

Страница 1: ...Doc no IZ OMX0012 1 PRODUCT NAME Ionizer Gun type MODEL Series Product Number IZG10 ...

Страница 2: ...le type IZG10 03 11 4 Function 12 4 1 Name of parts 12 4 2 LED indication 12 4 3 Mode setting switch 13 4 4 Emitter maintenance cleaning and replacement 14 4 5 Alarm function 16 5 Performance 17 5 1 Installation distance and Discharge time Discharge time of 1000V 100V 17 5 2 Static neutralization range Discharge time of 1000V 100V 18 5 3 Pressure Flow characteristics 19 6 Dimensions 19 7 Specifica...

Страница 3: ...f equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to rem...

Страница 4: ...e failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this 1 year warranty A vacuum pad is a consumable part so it is warranted for a year after it is delivered Also even within the warranty period the wear of a product due to the use of the vacu...

Страница 5: ...ment confirm the required cleanliness before use Fine particles are generated due to wear of emitters and motor sliding during operation 1 Before wiring ensure that the power supply capacity meets the specification and that the voltage is within the specification Product damage or malfunction can result 2 To maintain product performance the power supply should be UL Class 2 certified by National E...

Страница 6: ...erformance and may also cause operation failure or an accident 12 If a valve is placed immediately before the product instantaneous air release may occur when compressed air is supplied regardless of the trigger operation of the product 13 If the supply pressure of compressed air is less than the product specification pressure 0 05MPa the valve in the product may not open or close Use the product ...

Страница 7: ...o obtain clean compressed air air quality of Class 2 4 3 2 5 3 2 6 3 or higher according to ISO 8573 1 2010 JIS B8392 1 2012 is recommended for operation 7 The product and AC adapter are not resistant to lightening surge 8 Influence on the implantable medical equipment Electromagnetic waves emitted by this product may adversely affect implantable medical devices such as implantable cardiac pacemak...

Страница 8: ...ric shock or fire The product will not be guaranteed if it is disassembled and or modified 6 Do not operate the product with wet hands It may cause electric shock or other accidents 1 Please check the following points in the regular maintenance and replace the parts as necessary a Emitter is dirty or worn out b Loosening or damage of the nozzle c Squeezing or twisting of the tubing that is connect...

Страница 9: ...an Rated voltage 125V plug JIS C8303 inlet IEC60320 C13 The nozzle specified for the product Do not use other nozzles Otherwise static neutralizing performance will be adverselyaffected Nozzle One touch fitting 1 2 Accessories AC adapter IZG10 CG AC adapter Type With AC cordNote Without AC cord 2 Symbol 1 Note The AC cord is only for use in Japan Rated voltage 125V plug JIS C8303 inlet IEC60320 C1...

Страница 10: ...ルト2個付属 2 How to Use 2 1 Procedures to operation Start Wiring of ionizer Compressed air supply Refer to 3 Wiring Air piping Power supply ON Completed Protection cap Remove when used Provided together with 1 felt pad grindstone 1 rubber grindstone and 2 replacement felt pads Provided together with 10 replacement felt pads Provided together with 1 replacement rubber grindstone ...

Страница 11: ...2 Power supply cable type IZG10 03 Route the external equipment for the power supply and external switch signal input prepared by the customer according to the signal name on the power supply cable wiring table Ground the green F G correctly The static neutralizing performance is maintained by keeping its potential the same as the reference potential Power supplyconnector Ionizer Connection Power ...

Страница 12: ... port 7 Power supply connector Connector to input the signal for power supply F G Grounding and external switch 8 Operation LED Illuminate the object during static neutralization 4 2 LED indication 1 2 3 LED indication No Indication Colour Name Description 1 PWR Green Power supply indicator Green LED turns ON when power is supplied and the LED flashes when the voltage is outside of the specificati...

Страница 13: ...o 9 Blows ionized air intermittently Pulse frequency 5 Hz Trigger setting Trigger ON is enabled by inputting either the main unit trigger or external switch signal Trigger linked Set No 0 and No 5 Trigger ON OFF and blow ON OFF are linked Trigger locked Set No 1 and No 6 Blow ON is maintained when trigger operation is ON When the trigger operation is ON again the blow is OFF OFF timer Set No 2 to ...

Страница 14: ...e emitters are touched while the product is energized this may cause an electric shock or accident Since the tip of the emitter is pointed there is a danger of injury if touched When replacing the emitter assembly use a tool such as pliers to avoid direct contact with the tip of the emitter Cleaning of the emitter Using the cleaning kit saturate the felt with industrial alcohol insert it into the ...

Страница 15: ...assembly by rotating it as shown in the figure below with the protective cap attached Always remove the protective cap after mounting the emitter assembly Be careful when removing the cap as there is a danger of injury due to the emitter tip Hand tighten the nozzle in the direction shown below until it does not turn any more The recommended tightening torque by hand tightening is 0 1 to 0 2 N m St...

Страница 16: ... power back on 2 Incorrect high voltage If the high voltage output drops during operation ION HV LED red turns ON to notify the error When the failure occurs ion generation will be stopped The decrease of high voltage output could be caused by abnormal discharge due to condensation or dust on the emitters In order to clear the alarm remedy the cause of the abnormality and supply power again 3 CPU ...

Страница 17: ... 2 5 3 0 3 5 4 0 4 5 5 0 0 150 300 450 600 750 900 1050 1200 1350 1500 Discharge time sec Installation distance mm 0 05MPa 0 1MPa 0 2MPa 0 3MPa 0 4MPa 0 5MPa 0 6MPa 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 0 150 300 450 600 Discharge time sec Installation distance mm 0 05MPa 0 1MPa 0 2MPa 0 3MPa 0 4MPa 0 5MPa 0 6MPa Mode setting switch Pulse blow 5 6 7 8 Flow rate adjustment indicator 2 Flow ra...

Страница 18: ... L min ANR 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance mm 2 5s 2s 1 5s 1s 0 5s 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance mm 2 5s 2s 1 5s 1s 0 5s 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 1050 1200 1350 1500 Distance mm 1 5s 1s 0 5s 2s 200 150 100 50 0 50 100 150 200 0 150 300 450 600 750 900 105...

Страница 19: ...450 500 0 0 1 0 2 0 3 0 4 0 5 0 6 Flow rate L min ANR Supply pressure MPa Indicator maximum Indicator 7 Indicator 6 Indicator 4 Indicator 2 Indicator 0 6 Dimensions Ionizer IZG10 01 Power supply connector One touch fitting Applicable tube O D Table 1 Table 1 Applicable tube O D ø8 mm ø5 16 inch IZG10 08 01 IZG10 09 01 Models ...

Страница 20: ...IZG10 CG2 Not included Models AC cord Power supply cable 24VDC IZG10 CP Power supply cable 24VDC Semi stripped terminal Cable specification 4mm Number of cable wire Size Sheath material O D Insulator outside diameter Identification colour Nominal cross section of the conductor 4pcs AWG26 0 15mm2 0 85mm Red Black White Green Lead free PVC ...

Страница 21: ...d Directive CE Measurement values based on a charged plate dimensions 150 x 150 mm electrostatic capacity 20pF defined by ANSI standard ANSI ESD STM3 1 2015 Distance between charged plate and ionizer 150 mm Air purge 0 2 MPa Model Ion generation method Method of applying voltage Applied voltage Note 1 Air Clean dry air Offset voltage Note 2 Power supply voltage Current consumption Ambient temperat...

Страница 22: ...ve the problem of the entry of foreign matter into the nozzle and turn on the power again NDL alarm output Main unit LED display Discharge amount is reduced due to foreign matter adhering to the emitter or wear of the emitter Replace the emitter when repeatedly outputting an alarm while performing maintenance on the emitter Insufficient blow Air source flow rate adjustment Insufficient amount of b...

Страница 23: ...da Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2020 SMC Corporation All Rights Reserved ...

Отзывы: