HRX-OM-W002-A
Chapter 5 Display and Setting of Various Functions
HRR Series
5.3 List of parameters
5-11
5.3.8
Reset menu
Table
5.3-8
Reset menu parameter list
1
Can only be set with air-cooled type.
2
Can only be set with option DM (Electric conductivity control function, DI water (pure water)
piping).
5.3.9
Information Monitor Setting Menu
Table
5.3-9
Information monitor setting menu Parameter list
1 Only displayed on air-cooled type.
2 Displayed when option DM (Electric conductivity control function, DI water (pure water) piping).
Initial value
Select/setting range
TOP
screen
-
RST
-
MENU
No.1
screen
Set data reset
NO
NO/YES
ALL⇒RESET
No.2
screen
Reset of pump operation time
NO
NO/YES
PUMP.T⇒RESET
No.3
screen
Reset of compressor operation time
NO
NO/YES
COMP.T⇒RESET
No.4
screen
Reset of fan operation time *1
NO
NO/YES
FAN.T⇒RESET
No.5
screen
Reset of dust-proof filter operation time *1
NO
NO/YES
FLTR.T⇒RESET
No.6
screen
Reset the DI filter operation time *2
NO
NO/YES
DI.T⇒RESET
No.7
screen
Solenoid valve for electric conductivity
control Forced OPEN *2
OFF
OFF/ON
DI⇒VALVE
5.5.6
ScreenNo.
Item
Display unit
Reference
page
Upper stage(White)
Lower stage
(Green)
TOP
screen
-
MENU
-
No.1
screen
Model Cooling capacity / method
XXX-X
-
No.2
screen
Model Power supply / Options
-DMTUY
-
No.3
screen
Program number
PG.NO
-
No.4
screen
Program version
PG.VER
-
No.5
screen
Thermo-chiller accumulated operation time
RUN.T
H
No.6
screen
Accumulated operation time of pump
PUMP.T
H
No.7
screen
Accumulated operation time of compressor
COMP.T
H
No.8
screen
Accumulated operation time of fan
FAN.T
H
No.9
screen
Used time of dust filter
1
FLTR.T
H
No.10
screen
Used time of DI filter
1
DI.T
H
No.11
screen
Instantaneous power failureoccurrence count
POW.F
-
5.5.7
Display in the range of 0~1,000,000
Display in the range of 0~1,000,000
Display in the range of 0~1,000,000
Display in the range of 0~1,000,000
Display in the range of 0~1,000,000
Display in the range of 0~1,000,000
INFO
HRR
20
Program number
Program version
Display in the range of 0~1,000,000
ScreenNo.
Item
Display unit
Unit
display
Reference
page
Upper stage(White)
Lower stage
(Green)
Содержание HRR012-A*-20 Series
Страница 14: ...HRX OM W002 A Chapter 1 Safety Instructions 1 8 Material Safety Data Sheet MSDS HRR Series 1 8...
Страница 110: ...HRX OM W002 A Chapter 5 Display and Setting of Various Functions 5 5 Advanced setting mode HRR Series 5 62...
Страница 138: ...HRX OM W002 A Chapter 8 Control Inspection Exchange and Cleaning 8 5 Electrical schematic diagram HRR Series 8 18...
Страница 156: ...HRX OM W002 A Chapter 9 Documents 9 9 Daily Check HRR Series 9 18...
Страница 159: ......