-27-
No.EX
※※
-OMZ0016
I/O Configurator (NFC version)
EXW1 series supports Ver. 2.9.0 and later versions of the I/O Configurator. In order to use the I/O
Configurator (NFC version) it is necessary to install a driver etc. in advance and set the NFC reader/writer on
the computer.
This section describes the installation, screen layouts and operations of the I/O Configurator (NFC version).
The I/O Configurator (NFC version) can be used to check the parameter setting of the wireless unit and the
contents and status of the constructed wireless system, using an NFC reader/writer and a PC.
Refer to the operation manual for the I/O Configurator (NFC version) for details of the I/O Configurator (NFC
version).
SMC Wireless Communication System I/O Configurator (NFC version)
The I/O Configurator (NFC version) can be used to check the parameter setting of the wireless unit
and the contents and status of the constructed wireless system, using an NFC reader/writer and a PC.
There are two types of settable parameters which can be read or written
when no power is supplied
to the product
and the parameters which can be read or written
only when power is supplied to
the product
.
The figure below shows the image of connected I/O Configurator (NFC version) and wireless unit.
Connected I/O Configurator (NFC version) and wireless unit.
*: For information on compatible NFC readers/writers, refer to the operation manual for the I/O Configurator
(NFC version).
I/O Configurator
PC
NFC reader/writer
Base
Remote
Establish communication
by adjusting the position so that
the height from the centre of the
NFC R/W antenna to the
"○"
on
the wireless unit is 1 cm or less.
•Communication timing
The NFC communication is not accessed all the time. Therefore,
it is necessary to update
the contents displayed on the screen by clicking the "Refresh button" when reading the
parameters.
The changed parameters are enabled after the product is powered on or by pressing the
reset button on the I/O Configurator screen.
As the parameter setting requires time for
settlement, do not turn off the power supply for two seconds.
•To change the unit to be set
As the settings between the Base and Remote are different, it is necessary to update the
displayed parameter by clicking the "Refresh button" on the screen of the I/O Configurator
after changing the unit in which the parameters are to be set.
PC/SC driver
Memory area where
power supply is
necessary.
Memory area where
power supply is
necessary.