background image

 EXW1-TF222-092EN-A 

Page 1 of 2 

 

 

Instruction Manual 

SMC Wireless Adaptor  
Series EXW1-A11N-X1 

 

 

 

The intended use of this product is to provide a wireless communication 

between wireless adaptors via a wired connection using Air Management 

Hub.

 

1 Safety Instructions 

These safety instructions are intended to prevent hazardous situations 

and/or equipment damage. These instructions indicate the level of 

potential hazard with the labels of “Caution,” “Warning” or “Danger.” 

They are all important notes for safety and must be followed in addition 

to International Standards (ISO/IEC)

 *1)

, and other safety regulations. 

*1)

 ISO 4414: Pneumatic fluid power - General rules relating to systems. 

ISO 4413: Hydraulic fluid power - General rules relating to systems. 

IEC 60204-1: Safety of machinery - Electrical equipment of machines. 

(Part 1: General requirements) 

ISO 10218-1: Manipulating industrial robots -Safety. etc. 

  Refer to product catalogue, Operation Manual and Handling 

Precautions for SMC Products for additional information. 

  Keep this manual in a safe place for future reference. 

 

Caution 

Caution indicates a hazard with a low level of risk which, if 

not avoided, could result in minor or moderate injury. 

  Warning 

Warning indicates a hazard with a medium level of risk 

which, if not avoided, could result in death or serious injury. 

  Danger 

Danger indicates a hazard with a high level of risk which, if 

not avoided, will result in death or serious injury. 

Warning 

 

Always ensure compliance with relevant safety laws and 

standards. 

All work must be carried out in a safe manner by a qualified person in 

compliance with applicable national regulations. 

 

2 Specifications 

2.1  General specifications 

 

 

 

 

 

 

 

 

 

 

 

 

2 Specifications (continued) 

2.2  Electrical specifications 

Item 

Specification 

Power supply voltage for 

control 

12 VDC -10% to 24 VDC +10% 

Current consumption 

50 mA or less 

 

2.3  Wireless Communication specifications 

Item 

Specifications 

Protocol 

SMC original protocol 

(SMC encryption) 

Radio wave type (spread) 

Frequency Hopping Spread Spectrum 

(FHSS) 

Frequency band 

2.4 GHz (2403 to 2481 MHz) 

Frequency channels 

79 ch (Bandwidth: 1.0 MHz) 

Communication speed 

1 Mbps 

Communication distance 

Up to 100 m line of sight  

(Depends on the environment) 

Radio Law certificates 

Refer to the operation manual. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 Name and Function of parts 

 

Wireless Adaptor 

 

 

 

No. 

Item 

Description 

Connector 

M8 connector for cable to wireless 

base or remote. 

Nut 

For fixing to Air Management Hub. 

LED display 

Indicates the status of the adaptor. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

4 Installation 

4.1  Installation 

Warning 

  Do not install the product unless the safety instructions have been read 

and understood. 

 

4.2  Mounting 

Mount the wireless adaptor bracket to the Air Management Hub using the 

screw attached to the Air Management Hub. (Recommended torque: 0.3 

±10% N•m). Then attach the cable EXW1-AC1-X1 to the wireless adaptor 

and Air Management Hub. (When inserting the cable into the Wireless 

adaptor, use an insertion force of 10 N or less). 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

Mount the adaptor to the bracket of the Air Management Hub using the 

M10 nut already installed to the wireless adaptor (Recommended torque: 

0.9 ±10% N•m). 

 

 

4 Installation (continued) 

4.3  Environment 

Warning 

  Do not use in an environment where corrosive gases, chemicals, salt 

water or steam are present. 

  Do not use in an explosive atmosphere. 

  Do not expose to direct sunlight. Use a suitable protective cover. 

  Do not install in a location subject to vibration or impact in excess of 

the product’s specifications.  

  Do not mount in a location exposed to radiant heat that would result in 

temperatures in excess of the product’s specifications. 

 

 

 

 

5 Wiring 

5.1  Wiring Connections 

 

Connector 

No. 

Signal 

M8, 4-pin, plug 

A-coded 

24 V (US1) 

 

Internal Bus B 

0 V (US1) 

Internal Bus A 

 

 

Caution 

  The EXW1-AC1-X1 is the cable which should be used for connection 

to the Air Management Hub.  

Radio laws require cables to be less than 3  m long, shielded and 

twisted pairs. 

 

 

6 LED Display 

  The LED indicators on the wireless adaptor indicate the power supply, 

communication and diagnostic status. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item 

Specification 

Enclosure rating 

IP67 

Ambient operating temperature 

-10 to +50

°

Ambient storage temperature  

-20 to +60

°

Ambient humidity 

35 to 85% RH (no condensation) 

Withstand voltage 

500 VAC for 1 minute between 

external terminals (including the FE 

terminal) and enclosure screws 

Insulation resistance 

10 MΩ or more (500 VDC between 

external terminals (including the FE 

terminal) and enclosure screws 

Vibration resistance 

EN61131-2 compliant: 

 f < 8.4 Hz 3.5 mm 

8.4 

 f < 150 Hz 9.8 m/s

2

 

Impact resistance 

EN61131-2 compliant: 

147 m/s

2

, 11 ms 

Weight 

30 g 

 

ORIGINAL INSTRUCTIONS 

 

 

 

LED   LED Colour 

Operation 

PWR 

Green LED 

ON 

US1 (for control) power supply is ON 

Red LED ON  Unrecoverable error is detected. 

OFF 

US1 (for control) power supply is OFF 

W-SS 

Green LED 

ON 

The level of received radio wave power is 3. 

Green LED 

flashing 

(1 Hz) 

The level of received radio wave power is 2. 

Green LED 

flashing  

(2 Hz) 

The level of received radio wave power is 1. 

Red LED 

flashing 

No Remotes are connected. 

OFF 

Wireless Base or Remote is not registered. 

 