background image

-2- 

 

No.D-

S-OMB0023-B

 

 

Safety Instructions

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of "Caution", "Warning" or "Danger".

 

They are all important notes for safety and must be followed in addition to International Standards 
(ISO/IEC)

*1)

, and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

IEC 60204-1: Safety of machinery -- Electrical equipment of machines. (Part 1: General requirements)

 

ISO 10218: Manipulating industrial robots -Safety.

 

etc.

 

 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could 

result in minor or moderate injury.

 

 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, 

could result in death or serious injury.

 

 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will 

result in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the 

equipment or decides its specifications.

 

Since the product specified here is used under various operating conditions, its compatibility with specific 
equipment must be decided by the person who designs the equipment or decides its specifications 
based on necessary analysis and test results. 
The expected performance and safety assurance of the equipment will be the responsibility of the 
person who has determined its compatibility with the product. 
This person should also continuously review all specifications of the product referring to its latest catalog 
information, with a view to giving due consideration to any possibility of equipment failure when 
configuring the equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The assembly, operation and maintenance of machines or equipment including our products must be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is 

confirmed.

 

1. The inspection and maintenance of machinery/equipment should only be performed after measures to 

prevent falling or runaway of the driven objects have been confirmed.

 

2. When the product is to be removed, confirm that the safety measures as mentioned above are 

implemented and the power from any appropriate source is cut, and read and understand the specific 
product precautions of all relevant products carefully. 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

 

4. Contact SMC beforehand and take special consideration of safety measures if the 

product is to be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place 

exposed to direct sunlight. 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special 

safety analysis.

 

4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using 

a mechanical protective function, and periodical checks to confirm proper operation. 

Содержание D-S7 Series

Страница 1: ...No D S OMB0023 B PRODUCT NAME Solid State Auto Switch MODEL Series Product Number D S9 D T99 D S7 D T79...

Страница 2: ...afety Instructions 2 Model Indication and How to Order 8 Summary of Product parts 11 Definition and terminology 11 Mounting and Installation 12 Installation 12 Circuit diagram 14 Troubleshooting 15 Sp...

Страница 3: ...equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly...

Страница 4: ...responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the...

Страница 5: ...outside of the specifications Do not use for flammable or harmful fluids Fire malfunction or damage to the product can result Verify the specifications before use Do not operate in an atmosphere cont...

Страница 6: ...Auto switches mounted parallel with each other keep 40 mm or more between actuator tubes to prevent influence malfunction due to magnetic interference Keep the allowable displacement for each Auto swi...

Страница 7: ...xists It can cause a malfunction of the Auto switch or demagnetization of a magnet inside actuator Do not use the Auto switch in an environment where the Auto switch is always splashed with water drip...

Страница 8: ...their instructions Turn the power on after connecting a load Otherwise it can cause excess current causing instantaneous breakage of the Auto switch Maintenance Perform maintenance and check regularl...

Страница 9: ...8 No D S OMB0023 B Model Indication and How to Order...

Страница 10: ...ons Insert the connector until the sleeve hit the switch so that projected part of the connector engage the groove of inserted portion Tighten the tightening ring afterwards Water tightness may be det...

Страница 11: ...10 No D S OMB0023 B D S991 D S9P1 D T991 D S99V1 D S9PV1 D T99V1 The description of parts is consistent regardless of the type of switch The drawing above is the right handed type...

Страница 12: ...ding of the output to other machines Internal voltage drop The voltage applied between the COM and signal line when the Auto switch turns on Current leakage The current flowing to the load when the Au...

Страница 13: ...e the clamp for actuator after confirms that the actuator built in magnet Proper tightening torque The tightening torque of the M3 mounting screw must be 0 5 Nm 5 1 kgf cm D S79 D S7P D T79 D T79C 1 A...

Страница 14: ...ng block A moves inside the groove move it to the mounting position beforehand After the actuated position has been adjusted with the cross recessed round head screw 1 use the auto switch Setting the...

Страница 15: ...d load are separate D S7P D S9P V D T79 C D T99 V Sink input mode D T79 C D T99 V Source input mode The number marked on each lead wire color shows the pin number of pre wired connector PLC connector...

Страница 16: ...urn on The operation LED doesn t light up The operation LED doesn t go off Switch failure Misapplication Switch failure Trouble No 7 The operation LED doesn t light up The operation LED doesn t go off...

Страница 17: ...agnetic shield between cylinders Incorrect setting mounting position Short stroke Check if the condition is as below Switch operation range Piston stroke Displace the switch set position from the oper...

Страница 18: ...e conductor Strong magnet Use the shield between magnetic field generating source and cylinder Influence of magnetic field of adjacent cylinder 20 mm or less Keeps cylinder away 40 mm or more Use magn...

Страница 19: ...lead wire Bend radius Tensile force to lead wire Correct wiring Correct tensile force increase bend radius Malfunction due to turbulence magnetic field Presence of magnetic field generating source aro...

Страница 20: ...40 mA or less 2 5 to 40 mA Internal voltage drop 0 8 V or less at load current of 10 mA 2 V or less at load current of 40 mA 4 V or less Current leakage 100 A or less at 24 VDC 0 8 mA or less Indicat...

Страница 21: ...20 No D S OMB0023 B Dimensions D S791 D S7P1 D T791 D S792 D S7P2 D T792...

Страница 22: ...21 No D S OMB0023 B D T791C D T792C...

Страница 23: ...22 No D S OMB0023 B D S991 D S9P1 D T991 D S992 D S9P2 D T992...

Страница 24: ...23 No D S OMB0023 B D S99V1 D S9PV1 D T99V1 D S99V2 D S9PV2 D T99V2...

Страница 25: ...24 No D S OMB0023 B Pre wired connector D APC D BPC D DPC...

Страница 26: ...vision July 2019 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and an...