-84-
No.PF
※※
-OMA1007
■
[F81] Security code
The security code can be turned on and off and the security code can be changed when unlocked.
<Operation>
Display [F81] by pressing the UP or DOWN button in function selection mode.
Press the SET button.
Move on to select security code.
Select security code
Press the UP or DOWN button to select security code.
Check of the setting of security code
Press the UP or DOWN button to change
the value.
Press the SET button to move to the digit
to the right.
(The default setting is [000])
Press the SET button for 1 second or longer.
•When the security code is correct, move on to the security code setting.
•If the security code entered is incorrect, [FAL] will be displayed, and the
security code must be entered again.
If the wrong security code is entered 3 times, [nG] is displayed on the
main display and the device returns to function selection mode.
[oFF] is selected.
Press the SET button
to return to function
selection mode.
[on] is selected.
Press the SET button to set.
Move on to check the setting of
security code.
Move on to the changing of security
code.
Содержание AMS20
Страница 1: ...No PF OMA1007 PRODUCT NAME Air Management System MODEL Series Product Number AMS20 AMS30 AMS40 AMS60...
Страница 13: ...12 No PF OMA1007 Model Indication and How to Order Air Management System Standby E P regulator type...
Страница 14: ...13 No PF OMA1007 Air Management System Standby regulator type...
Страница 40: ...39 No PF OMA1007...
Страница 124: ...123 No PF OMA1007 EXA1 60 PN EN...
Страница 126: ...125 No PF OMA1007 EXA1 60 SA Refer to separate operation manuals for other AMS components...