[F 0] Reference condition/Units selection function
Reference condition
Standard condition or normal condition can be selected.
Standard condition and normal condition are defined as follows:
•Standard condition: Displayed flow rate which is converted to volume at 20 °C, 101.3 kPa (absolute pressure).
•Normal condition: Displayed flow rate which is converted to volume at 0 °C, 101.3 kPa (absolute pressure).
Units selection function
This setting is only available for models with the units selection function.
∗
: kPa/MPa can be selected if the product does not have the unit selection function.