56-VV5QC*1-TFL33-C

 

4 Settings (continued) 

• 

Turn anti-clockwise to release. 

 

Figure 14 

 

Locking type (manual). 56-VQC1000/2000 

• 

Push down the manual override button with a small flat head screwdriver 
or finger until it stops and turn 90° clockwise to lock. 

• 

Turn anti-clockwise to release 

 

 

Figure 15 

 
 

Slide locking type (manual). 56-VQC1000/2000 

• 

Push down the manual override button with a small flat head screwdriver 
or finger until it stops and slide towards the coil to lock. 

• 

To unlock, slide the override away from the coil. 

 

 

Figure 16 

 

5 Circuit Symbols 

 

Figure 17 

 
 
 

6 Options 

6.1  Mounting 

 

• 

Disconnect  power  supply  before  removing  or  making  electrical 
connections. 

 

 

• 

Do not use options other than specified in the 56-VQC catalogues. 

• 

The options are standard parts without “56-“ prefix. 

 

Removal and mounting procedure: 

• 

Blanking  plate  assembly,  individual  SUP  spacer  and  individual  EXH 
spacer are mounted in the same way as valves. Please refer to section 
3.5 Mounting. 

 

6.2  Adding manifold stations (see Figure 18) 

 

• 

When  adding  manifold  stations,  ensure  the  correct  number  of  power 
saving  units  are  installed,  as  operating  the  valves  could  exceed  the 
marked surface temperatures. 

• 

1 to 12 solenoids – 1 power saving unit required. 

• 

13 to 24 solenoids – 2 power saving units required. 

• 

Install 56-VQC valves only. 

 

 

• 

Undo the bolts (Item 3) to the tie-rods and remove the U-side end plate 
assembly (Item 6). If DIN rail is fitted, first release the DIN rail. 

• 

Screw  in  tie-rod  extensions  (Item  2)  supplied  with  the  manifold  block 
assembly  (standard  VQC  type)  and  assemble  the  manifold  block  (Item 
1). 

• 

Re-assemble the U-side end plate assembly (Item 6) and tighten the tie-
rod screws (Item 3) to torque shown in Table 2.  

• 

Ensure all seals and gaskets are installed. 

• 

Install  valve  to  added  manifold  block  as  described  in  section  3.5 
Mounting. 

• 

Check the correct number of power saving units (Item 5) are present. 

 

Valve Series 

Tightening Torque N•m 

56-VQC1000 

0.85 to 0,95 

56-VQC2000 

1,2 to 1,6 

56-VQC4000 

1,7 to 2,3 

Table 2 

 

 

Figure 18 

 

6.3  Adding power saving unit (Item 5) 

• 

If a second power saving unit is required due to exceeding 12 solenoids 
on the manifold, contact SMC for the correct part. 

• 

The second power saving unit must be positioned next to the D-side end 
plate assembly (Item 4). 

 

7 How to Order 

Refer to the catalogue for this product. 
 

8 Outline Dimensions (mm) 

Refer to the catalogue for this product. 
 

9 Maintenance 

9.1  General Maintenance 

 

• 

Not following proper maintenance procedures could cause the product to 
malfunction and lead to equipment damage. 

• 

If  handled  improperly,  compressed  air  can  be  dangerous.  Maintenance 
of pneumatic systems should be performed only by qualified personnel. 

• 

Before performing maintenance, turn off the power supply and be sure to 
cut  off  the  supply  pressure.  Confirm  that  the  air  is  released  to 
atmosphere. 

• 

After installation and maintenance, apply operating pressure and power 
to the equipment and perform appropriate functional and leakage tests to 
make sure the equipment is installed correctly. 

• 

Do not make any modification to the product. 

• 

Do  not  disassemble  the  product,  unless  required  by  installation  or 
maintenance instructions. 

• 

Drain: remove condensate from the filter bowl on regular basis. 

• 

Low frequency operation:

 

Switch valves at least once every 30 days to prevent malfunction. Also, 
in order to use it under optimum state, conduct a regular inspection once 
every 6 months.

 

• 

Filters and strainers:

 

Be careful regarding clogging of filters and strainers 

Replace  filter  elements  after  one  year  of  use,  or  earlier  if  the 
pressure drop reaches 0.1 MPa. 

Clean strainers when the pressure drop reaches 0.1 MPa. 

 

9.2  Replacing One-touch fittings 

• 

Cylinder port fittings are available in cassette type and can be replaced 
easily. 

 

56-VQC 1000/2000 

• 

Remove the valve. 

• 

Extract clip with flat head screwdriver. 

• 

Pull fitting to remove. 

• 

Refitting is the reversal of removal. 

 

Figure 19 

 

Fitting assembly part no. 

Applicable tube O.D. 

56-VQC1000 

56-VQC2000 

Ø3.2 

VVQ1000-50A-C3 

Ø4 

VVQ1000-50A-C4 

VVQ1000-51A-C4 

Ø6 

VVQ1000-50A-C6 

VVQ1000-51A-C6 

Ø8 

VVQ1000-51A-C8 

M5 

VVQ1000-50A-M5 

Ø1/8” 

VVQ1000-50A-N1 

Ø5/32” 

VVQ1000-50A-N3 

VVQ1000-51A-N3 

Ø1/4” 

VVQ1000-50A-N7 

VVQ1000-51A-N7 

Ø5/16” 

VVQ1000-51A-N9 

Table 3 

9 Maintenance (continued) 

56-VQC 4000

 

• 

Remove the valve. 

• 

Extract clip with flat head screwdriver. 

• 

Pull fitting to remove. 

• 

Refitting is the reversal of removal. 

 

 

Figure 20 

 

Fitting assembly part no. 

Applicable tube O.D. 

56-VQC4000 

Ø8 

VVQ4000-50B-C8 

Ø10 

VVQ4000-50B-C10 

Ø12 

VVQ4000-50B-C12 

Ø1/4” 

VVQ4000-50B-N7 

Ø5/16” 

VVQ4000-50B-N9 

Ø3/8” 

VVQ4000-50B-N11 

Table 4 

 

10 Limitations of Use 

 

• 

Do not exceed any of the specifications in section 2 of this document or 
the specific product catalogue. 

 

10.1 Maintenance space 

• 

The installation should allow sufficient space for maintenance activities. 

10.2 Ambient environment 

• 

Use within the allowable ambient temperature range.  

10.3 Mounting orientation 

• 

In the case of a single solenoid, the mounting orientation is unrestricted. 
In the case of double solenoid or 3 position valves, mount so the spool is 
horizontal. 

• 

When  mounting  for  an  application  that  will  involve  vibration  or  impact, 
mount so the spool is at right angles to the direction of vibration. 

• 

Do not use in applications where vibration or impact exceed the products 
specification. 

 

11 Contacts 

AUSTRIA 

(43) 2262 62280-0  

LATVIA 

(371) 781 77 00 

BELGIUM 

(32) 3 355 1464  

LITHUANIA 

(370) 5 264 8126 

BULGARIA 

(359) 2 974 4492  

NETHERLANDS 

(31) 20 531 8888 

CZECH REP. 

(420) 541 424 611  

NORWAY 

(47) 67 12 90 20 

DENMARK 

(45) 7025 2900  

POLAND 

(48) 22 211 9600 

ESTONIA 

(372) 651 0370  

PORTUGAL 

(351) 21 471 1880 

FINLAND 

(358) 207 513513  

ROMANIA 

(40) 21 320 5111 

FRANCE 

(33) 1 6476 1000  

SLOVAKIA 

(421) 2 444 56725 

GERMANY 

(49) 6103 4020  

SLOVENIA 

(386) 73 885 412 

GREECE 

(30) 210 271 7265  

SPAIN 

(34) 945 184 100 

HUNGARY 

(36) 23 511 390  

SWEDEN 

(46) 8 603 1200 

IRELAND 

(353) 1 403 9000  

SWITZERLAND 

(41) 52 396 3131 

ITALY 

(39) 02 92711  

UNITED KINGDOM 

(44) 1908 563888 

 

URL : 

http// 

www.smcworld.com

 (Global)      http// 

www.smceu.com

 (Europe)

 

Specifications are subject to change without prior notice from the manufacturer.  
© 

2012 

SMC Corporation All Rights Reserved. 

Отзывы: